Comparison of propofol administration regulation by pharmacodynamic indicator esTEC (estimated target-effect- site concentration) versus BIS value

Author(s)
Yuka Matsuki Department of Anesthesiology & Reanimatology, University of Fukui Hospital, Fukui, Japan
Osamu Nagata Department of Anesthesiology,Center Hospital of the National Center for Global Health and Medicine, Tokyo, Japan
Yoshihiro Ogino Ventilator & Anesthesia Device Business Operations, NIHON KOHDEN Corporation, Tokyo, Japan
Yuko Nakanishi Department of Anesthesiology & Reanimatology, University of Fukui Hospital, Fukui, Japan
Kenji Shigemi Department of Anesthesiology & Reanimatology, University of Fukui Hospital, Fukui, Japan
Abstract
Background: Using an algorithm by which the effect-site concentration of propofol (esTEC) necessary for BIS level set from information input from BIS monitor and target controlled infusion (TCI) pump is estimated, we evaluated the accuracy of administration of propofol guided esTEC, whether it is equivalent to that guided BIS value. Methodology: The clinical data of 29 adult patients, who received head/neck surgery and 27 adult patients, who received gynecological surgery, in our hospital from February 2016 and December 2017 were analyzed. Patients were divided into 2 groups: BIS group (adjustment the propofol dose using a target BIS index of 35 to 55, head/ neck surgery n = 15, gynecological surgery n = 14); and esTEC group (adjustment the propofol based on esTEC45, head/neck surgery n = 14, gynecological surgery n = 13). The relevant data from 2 groups were collected and analyzed. For statistical analysis, the unpaired t-test, chi-squared test and Wilcoxon test were used, and p < 0.05 was considered statistically significant. Results were expressed as Results: For head and neck surgery, the percentage of time with BIS35-55 was significantly greater in the esTEC group than the BIS group (95 ± 5% and 81 ± 18%, respectively, p < 0.01), as was the percentage of time with BIS<55 (96 ± 5% and 86 ± 17%, respectively, p = 0.0274). For gynecological surgery as well, the percentage of time with BIS35-55 was significantly higher in the esTEC than the BIS group (95 ± 4% and 82 ± 13%, respectively, p < 0.01), as was the percentage of time with BIS<55 (97 ± 3% and 88 ± 15%, respectively, p = 0.0292). Conclusion: This investigation showed with surgeries at two sites and with patients of different characteristics that propofol dose adjustment based on esTEC could maintain BIS index within the target range similar to adjustment by an attending resident of anesthesia using the BIS index.
Publication Details
Page(s) 387-391
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 23, Issue: 4, Year: 2019

Request the full text from PASTIC

Keywords
esTEC, Estimated target effect-site concentration, Propofol effect-site concentration, BIS value