No Detail Found!

Conventional diagnosis for tuberculosis versus latest modalities at a tertiary care setting of Peshawar

Author(s)
Shazia Tariq Department of Microbiology Gajju Khan Medical College Swabi,KPK -,Pakistan
Maria khan Department of Microbiology Rehman Medical Institute,Peshawar -,Pakistan
Qurat ul ain Tariq Department of Basic Sciences Northwest School of Medicine,Peshawar -,Pakistan
Valeed Khan Department of Geniomics Rahman Medical Institute,Peshawar -,Pakistan
Naima Tariq Department of Basic Sciences khyber Girls Medical College,Peshawar -,Pakistan
Haroon Tariq Department of Basic Sciences Northwest School of Medicine,Peshawar -,Pakistan
Tariq Ahmed Department of Geniomics Rahman Medical Institute,Peshawar -,Pakistan
Abstract
Objective: To evaluate and compare the performance of Ziehl Neelsen (ZN) smearing, Lowenstein-Jensen (LJ) culture and real-time PCR analysis to detect Mycobacterium tuberculosis in pulmonary and extra-pulmonary specimens. Materials and Methods: A descriptive study conducted from January 2016 through December 2018, on a total of 293 clinical samples of patients suspected with pulmonary and extra-pulmonary tuberculosis at a tertiary hospital of Peshawar, Pakistan. Specimens were processed by ZN smearing, LJ culture and Real-time PCR technique for the detection of M.tuberculosis. The target for the amplification was a segment of IS6110 in the M.tuberculosis chromosome. Specificity and sensitivity were derived for each test and Fishers exact test was performed to examine significance of association between specimen types and each test. Results: Of the 293 samples, 165(56.3%) were from males and 128(43.7%) females. Mean age was 44 years (2-85 years). Specimen types included: CSF (30.4%), pleural fluid (4.1%), sputum (15%), urine (2.4%), synovial fluid (2.4%), other fluids (33.1%) and biopsies (12.6%). Using PCR as gold standard, ZN microscopy correctly identified 20.5% of total M.TB positive specimens and LJ culture detected 47.7%.Certain specimen types showed higher positivity rates of M.TB detection: synovial lfuid (42.9%), pleural fluid (41.7%)by PCR analysis. ZN microscopy was associated with the low positivity rates for all speci mens, the highest being 18.2% for sputum samples. Conclusion: Tuberculosis PCR is a more rapid and reliable test in the diagnosis and management of tuberculosis. Both Pulmonary and extra-pulmonary specimens exhibit greater positivity rates by PCR analysis than by LJ culture and ZN smearing. 
Publication Details
Page(s) 29-33
DOI DOI not available
Published Journal: Journal of Medical Science, Volume: 28, Issue: 1, Year: 2020

Request the full text from PASTIC

Keywords
sensitivity, Specificity, Tuberculosis, real-time, pulmonary, Polymerase chain reaction, Mycobacterium, extra-pulmonary
0

Citations

0

Downloads

51

Views