No Detail Found!

Combination of STOP-BANG score and mandibulohyoid distance in the prediction of difficult airway among obstructive sleep apnea patients

Author(s)
Kok Tong Lee Department of Anesthesiology and Intensive Care, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia.
Rhendra Hardy Mohamad Zaini Department of Anesthesiology and Intensive Care, School of Medical Sciences, UniversitiSains Malaysia, 16150 KotaBharu, Kelantan, Malaysia.; Hospital Universiti Sains Malaysia, 16150 Kota Bharu,Kelantan, Malaysia
Wan Mohd Nazaruddin Wan Hassan Department of Anesthesiology and Intensive Care, School of Medical Sciences, UniversitiSains Malaysia, 16150 KotaBharu, Kelantan, Malaysia.; Hospital Universiti Sains Malaysia, 16150 Kota Bharu,Kelantan, Malaysia
Chandran Nadarajan Hospital Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan, Malaysia; Department of Radiology, School of Medical Sciences, Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan, Malaysia
Yee Cheng Kueh Biostatistic Unit, School of Medical Sciences, Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan, Malaysia
Lee Min Foo Hospital Raja Perempuan Zainab II, 15200 Kota Bharu, Kelantan, Malaysia
Mohamad Ibariyah Iberahim Department of Anesthesiology and Intensive Care, School of Medical Sciences, Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan, Malaysia; Hospital Universiti Sains Malaysia, 16150 Kota Bharu, Kelantan, Malaysia
Soon Eu Chong Regenerative Medicine Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, 13200 Kepala Batas, Penang, Malaysia.
Abstract
This study was designed to evaluate the diagnostic performance of STOPBANGscore and mandibulohyoid distance (MHD) towards difficult laryngoscopyamong obstructive sleep apnea patients.Cross-Sectional StudyMethodology: Forty-one patients who had STOP-BANG scores of >3 and requiredtracheal intubation for general anesthesia were recruited in this cross-sectional study.MHD was measured through lateral cephalometry. After induction of anesthesia, ananesthesiologist who was blinded to patient’s profile performed a laryngoscopy andevaluated the Cormack-Lehane grading. Sensitivity, specificity, positive and negativepredictive values were determined for STOP-BANG and MHD. Binary logistic regression, receiver operating characteristics (ROC) and correlation analyses were employed. Results: Body mass index, neck circumference, and Mallampati scores were higher in the difficult laryngoscopy group. MHD was longer in difficult laryngoscopy group (25.40 ± 5.67 mm) than easy laryngoscopy group (20.17 ± 4.28 mm; p = 0.002). STOPBANG score was higher in difficult laryngoscopy group (5.86 ± 0.96 vs. 4.30 ± 0.98; p < 0.001). The combination of MHD and STOP-BANG score improved the quality of diagnostic test in predicting the laryngoscopy status with area under ROC of 87.6%, compared to each isolated parameter (i.e., MHD = 75.7%, STOP-BANG = 85.5%). Both MHD and STOP-BANG scores were significantly positive correlated (r = 0.42, p = 0.006). Conclusions: STOP-BANG score and MHD were useful in predicting difficult intubation. The diagnostic performance improved further when combining both parameters
Publication Details
Page(s) 204-210
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 23, Issue: 2, Year: 2019

Request the full text from PASTIC

Keywords
Difficult airway, Obstructive sleep apnea, STOP-BANG, Mandibulohyoid distance, Lateral cephalometry, Airway assessment
0

Citations

0

Downloads

67

Views