No Detail Found!

ESTIMATION OF GLOMERULAR FILTRATION RATE BY USING TC-99M DTPA PLASM A 1 SAMPLE M ETHOD, GATES M ETHOD, COCKCROFT-GAULT M ETH O D AND PR E D IC T E D CREATININE CLEARANCE M ETHOD: A PROSPECTIVE COMPARATIVE ANALYSIS WITH PLASM A 2 - SAMPLE CLEARANCE METHOD.

Author(s)
Nosheen Fatima Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Maseeh -Uz-Zaman Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Khalid Niaz Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Salman Habib Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Sharjeel Usmani Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Shahid Kamal Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Abid Hameed Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN), Karachi, Pakistan
Abstract
Study Objective: To compare diagnostic accuracy o f predicted clearance method, Gates method, CockcroftGault method and plasma 1- sample clearance method with plasma 2-samples clearance method with Tc99m DTPA for the estimation o f glomerular filtration rate(GFR). Study Design: Comparative study. Materials and Methods: This study included 91 consecutive patients who were referred for evaluation of renal function to the Nuclear M edicine section o f Karachi Institute o f Radiotherapy and Nuclear Medicine (KIRAN) from September 2004 to September 2005. The GFR was determined simultaneously by 5 methods including Plasma two-Sample Clearance method after Tc-99m DTPA injection (PSC 2); Plasma one-Sample Clearance m ethod after Tc-99 m DTPA injection (PSC 1); Gamma camera uptake m ethod after Tc-99m DTPA injection (Gates method); Predicted Creatinine Clearance by Modification of Diet and Renal Diseases (MDRD); and Cockcroft-G ault's equation for GFR estimation (CG). PSC 2 was chosen as a reference. Results: Out o f the 91 patients, 71 were males and 20 females with age ranging from 16-68 years. The regression equation of the PSC 1, Gates, MDRD and CG method against the PSC 2 was Y = 1.884 +0.970X (r=0.90, p<0.001, SEE value=10.23 ml/min/1.73m2), Y = - 9.944 + 1.083X (r=0.82, p<0.001, SEE value=11.02 ml/min/1.73m2), Y =25.606+ 0.640X (r=0.71, p=0.002, SEE value=15.56 ml/min/1.73m2), and Y =14.981+ 0.714X (r=0.77, p=0.002, SEE value=14.44 ml/min/1.73m2) respectively. In comparison with the GFR by PSC 2, the PSC 1 and Gates tended to overestimate by 1% (p=0.359) and 2% (p=0.265) respectively, MDRD and CG tended to underestimate GFR by 11% and 14% respectively (p<0.001). Conclusions: PSC 1 correlate well w ith PSC 2 and either can be substituted for the other as ideal GFR markers. The Gates method shows good correlation with PSC 2 however it is less precise than PSC 1. MDRD and CG m ethods due to sig n ifican t u n d erestim atio n are not co n sid ered as id eal G FR m arker.
Publication Details
Page(s) 65-70
DOI DOI not available
Published Journal: Journal of Dow University of Health Sciences, Volume: 2, Issue: 2, Year: 2008

Request the full text from PASTIC

Keywords
Cockcroft-Gault’s equation, Gates method, Plasma Sample Clearance
0

Citations

0

Downloads

41

Views