Assessment of seismic performance of submerged floating tunnel under multi-support seismic excitations

Author(s)
Naik Muhammad Department of Civil Engineering, Faculty of Engineering and Architecture,Balochistan, University of Information Technology, Engineering and Management Sciences, Quetta, Pakistan,
Saeed Ullah Jan Mandokhail Department of Civil Engineering, Faculty of Engineering and Architecture, Balochistan, University of Information Technology, Engineering and Management Sciences, Quetta, Pakistan,
Zafar Baloch Department of Civil Engineering, Faculty of Engineering and Architecture,Balochistan, University of Information Technology, Engineering and Management Sciences, Quetta, Pakistan,
Muhammad Habib Department of Civil Engineering, Faculty of Engineering and Architecture,Balochistan, University of Information Technology, Engineering and Management Sciences, Quetta, Pakistan,
Shamsher Sadiq Department of Civil Engineering, Faculty of Engineering and Architecture,Balochistan, University of Information Technology, Engineering and Management Sciences, Quetta, Pakistan,
Abstract
Submerged floating tunnel (SFT) is an innovative structural solution for the transportation infrastructure through sea straits, fjords, and inland waters and is an economical alternative to the longspan cable-supported bridge, immersed tunnel, or underground tunnel. An SFT is a massive cylindrical structure that floats at a certain depth below the water surface and subjected to extreme environmental conditions, such as waves, tsunamis and earthquakes. The seismic assessment of SFT supported by mooring cables, under multi-support seismic excitations needs to be evaluated in more detail. The time domain dynamic problem of SFT moored by inclined mooring cables/anchors is formulated and the geometric non-linear dynamic analysis of SFT subjected to hydrodynamic and seismic excitations is performed in this paper. The prototype of SFT to be constructed in Qindao Lake of China is analysed under multi-support seismic excitations. It was found that due to the fluid environment and flexible cables the effective seismic forces are dissipated well and SFT is stable under the spectrum compatible ground motions. However, the lateral component of seismic excitations produce larger responses compared to longitudinal one and may be critical for other case studies.
Publication Details
Page(s) 217-224
DOI DOI not available
Published Journal: NED University Journal of Research, Volume: 3, Issue: S-19, Year: 2020

Request the full text from PASTIC

Keywords
Multi-support seismic excitations, Submerged Floating Tunnel
0

Citations

0

Downloads

63

Views