Shear Behavior of Steel Fiber Reinforced Prestressed Concrete Beams

Author(s)
Muhammad Ahmad Department of Civil Engineering, University of Central Punjab, Lahore, Pakistan
Muhammad Mazhar Saleem Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
Muhammad Azhar Saleem Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
Ali Ahmed Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
Safeer Abbas Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan
Abstract
Prestressed concrete girders are the main superstructure elements in many bridge structures. Shear failures in these girders are undesirable due to brittle failure and little warning time. To prevent shear controlled brittle failure, it is normal practice to increase the amount of transverse reinforcement in flexural members. However, past studies have revealed that even higher transverse reinforcement ratios (i.e. > 4%) may not be able to eliminate shear failure in some cases. Moreover, the increased reinforcement makes it more difficult to place and consolidate the concrete. This research program aimed to investigate the feasibility of replacing traditional shear reinforcement in prestressed concrete beams with steel fibers. A total of 14 rectangular and 8 I-shaped prestressed concrete beams were investigated after subjecting them to a two-point loading test. The beams were cast with steel fiber ratios ranging from 0.75% to 2.00%. Experimental results revealed that the inclusion of steel fibers in concrete mix improved the shear strength of rectangular and I shaped prestressed beams. It was observed that on adding 1% fibers, the shear strength of I-beams enhanced by 23%. Moreover, in some cases, the addition of steel fibers also caused the shear failure mode to shift to flexural failure mode without traditional shear reinforcement. Furthermore, cracking behavior and ultimate strength were also improved. However, at high fiber dosages, balling of the fibers was observed and the load capacity decreased compared to beams with lower fiber contents.
Publication Details
Page(s) 93-103
DOI DOI not available
Published Journal: Pakistan Journal of Engineering and Applied Sciences, Volume: 27, Issue: 1, Year: 2020

Request the full text from PASTIC

Keywords
Shear failure, transverse reinforcement, pre-stressed concrete, steel fibers