No Detail Found!

The use of GIS and Geo-electric Techniques for Delineation Surface and Groundwater Potential in Kotli City, District Kotli, Azad Jammu and Kashmir, Pakistan

Author(s)
Abrar Niaz Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Mubashar Imtiaz Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Muhammad Rustam Khan Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Fahad Hameed Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Jawad Niaz Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Ali Yousaf Khan Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Kishwar Mehmood Institute of Geology, University of Azad Jammu and Kashmir, Muzaffarabad, P.O Box 13100, Azad Jammu and Kashmir, Pakistan
Abstract
The geo-electrical and Geographic Information System (GIS) techniques have been employed for modeling surface and groundwater bodies of the Kotli city and its surrounding areas in the District Kotli, Azad Jammu and Kashmir, Pakistan. The Landsat 8 imagery is used for modeling the surface water and Vertical Electrical Sounding (VES) method is applied for the delineation of subsurface lithology in the study area. A total number of 21 VES points have been collected by using Schlumberger configuration. The VES data was collected using ABEM Terrameter SAS 4000. The acquired data have been processed by using IPI2WIN (2008) software and the interpretation was carried out in terms of true resistivity and thickness of different layers of sedimentary strata. The groundwater potential zones (good and moderate) have been identified in the area. The thickness of aquifer varies from 20 m to 129 m. Most of aquifers are confined and of “A” (?1 < ?2 < ?3), “K” (?1 < ?2 > ?3) and “H” type (?1 > ?2 < ?3). The VES 1, 2, 10, 11, 12, 20 and 21 south western part of the study area showed poor to weak overburden protective capacity of the aquifers, hence are vulnerable to infiltrating fluids from storage facility or dumps.
Publication Details
Page(s) 1-15
DOI DOI not available
Published Journal: Pakistan Journal of Engineering and Applied Sciences, Volume: 26, Issue: 1, Year: 2020

Request the full text from PASTIC

Keywords
Digital Elevation Model, Geographic Information System, Vertical Electrical Sounding, Environment for Visualizing Image
0

Citations

0

Downloads

31

Views