No Detail Found!

Influence of electronic nicotine delivery systems (ENDS) in comparison to conventional cigarette on color stability of dental restorative materials

Author(s)
Fahim Vohra Department of Prosthetic Dental Science,College of Dentistry,King Saud University,RiyadhSaudi Arabia.
Abdulelah F. Andejani Department of General Dentistry,King Saud University,Riyadh 11545, Saudi Arabia.
Osamah Alamri Department of General Dentistry,College of Dentistry,King Saud University,Riyadh, Saudi Arabia.
Abdulaziz Alshehri Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
Rana S Al-Hamdan Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
Thamer Almohareb Department of Restorative Dental Sciences College of Dentistry,King Saud University,Riyadh, Saudi Arabia.
Tariq Abduljabbar Department of Prosthetic Dental Science, College of Dentistry,King Saud University, Riyadh Saudi Arabia.
Abstract
Objective: The use of Electronic Nicotine Delivery Systems (ENDS) is increasing rapidly. However, its discoloring effect on dental restorations is not known. This study aimed to evaluate the effect of ENDS aerosol when compared to conventional cigarette smoke (CS) on the color stability of dental ceramic (DC) and resin composite (RC). Methods: This research project was conducted from November 2018 to May 2019. In this study 30 discs each for DC and RC materials were fabricated to be equally divided into groups of exposure to CS, ENDS aerosol and storage in distilled water (No smoke; NS) respectively (n=10). Specimens were exposed for a total of 7 days, with a rate of 10 cycles per day, each cycle represented 10 puffs. The color change was assessed using the CIELAB color space, by calculating ΔE. Data was analysed using ANOVA and multiple comparisons test. Results: Ceramic specimens in CS (2.422 ± 0.771) and ENDS (2.396 ± 0.396) groups showed comparable ΔE (color change) (p=0.992). Similarly, composite specimens in CS (42.871 ± 2.442) and ENDS (46.866 ± 3.64) groups showed comparable ΔE (p>0.05). NS specimens in both composite and ceramic samples showed lower ΔE than CS and ENDS specimens respectively. Conclusions: Aerosol from Electronic nicotine delivery systems (ENDS) showed similar discoloration levels as cigarette smoking (CS). The level of discoloration for ceramic samples for both ENDS and CS was below clinically perceptible levels (Mean ΔE < 2.5). Discoloration of composite resin due to CS and ENDS was visually perceptible (Mean ΔE > 4.0).
Publication Details
Page(s) 993-998
DOI DOI not available
Published Journal: Pakistan Journal of Medical Sciences, Volume: 36, Issue: 5, Year: 2020

Request the full text from PASTIC

Keywords
Cigarette, resin composite, ceramic, Electronic nicotine delivery system
0

Citations

0

Downloads

58

Views