No Detail Found!

Establishment of Multi-Fluorescence Real-Time PCR Assay for GM Soybean Detection

Author(s)
Liming Dong Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Likun Long Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Zhenjuan Xing Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Congcong Li Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Yuxuan He Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Wei Yan Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Wei Xia Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Feiwu Li Institute of Agricultural Quality Standard and Testing Technology, Jilin Academy of Agricultural Sciences, Changchun, China
Abstract
In the past two decades, a growing number of genetically modified (GM) crops have been developed and commercialized worldwide. High-throughput methods for screening and identification of GM crops have become a requirement for food industry and government agencies. To effectively detect seven specific transgenic soybean lines named GTS40-3-2, MON89788, CV127, A5547-127, A2704-12, 305423, and 356043, seven different primer-probe sets (labeled with FAM, HEX, Taxas Red, Cy5, and Quasar 705) were designed for the multi-fluorescence real-time PCR (MF-RT-PCR) assay. Through a series of experiments and tests including of primer combination screening, system optimization, specificity test, sensitivity test, and applicability test, two GM soybean target specific systems, SOY-M1 and SOY-M2, were established. SOY-M1, a pentaplex PCR detection system, could efficiently identify Mon89788, A2704-12, 305423, and 356043, and SOY-M2, a tetraplex PCR detection system is able to detect GTS40-3-2 CV127, and A5547-127. The sensitivity of both systems is 0.1%. In summary, the MF-RT-PCR detection system established in this study is highly accurate, reliable, and efficient in detecting these seven soybean lines and their derivates.
Publication Details
Page(s) 292-298
Published Journal: International Journal of Agriculture and Biology, Volume: 24, Issue: 2, Year: 2020

Request the full text from PASTIC

Keywords
MF-RT-PCR, Event-specific, Genetically modified soybean
0

Citations

0

Downloads

72

Views