Feasibility ofuse ofcoveredstents in Coarctation ofthe Aorta andits immediate outcome

Author(s)
Ahsan Beg Quaid-e-Azam Medical College,Bahawalpur,Pakistan
Masood Sadiq The Chidren's Hospital and Institute of Child Health,Lahore,Pakistan
Asif Ur Rehman Punjab Institute of Cardiology, Lahore,Pakistan
M Younas Chauhdary Parvaiz Elahi Institute of Cardiology,Multan-,Pakistan
Tauseef Asma Chauhdary Parvaiz Elahi Institute of Cardiology,Multan-,Pakistan
Abstract
BACKGROUND:Endovascular stenting in coarctation of the aorta is preferable in adolescents and adults, as it is carries less risk of restenosisand aneurysm formation. There is limited study data for early results of using covered stents, as primary treatment in a developing country. Inour setup repeat intervention and follow up are main challenges.OBJECTIVE: To see the feasibility of use of covered stents in coarctation of aorta and its immediate outcome.MATERIAL AND METHODS: This was a case series of patients with coractation of aorta. A total of 22 patients were included regardless ofgender with age about 18 years. Twenty two patients were implanted 23 covered stents (Cheatham-Platinum stents) at a single center, CPEInstitute of Cardiology, Multan, Pakistan. One patient had emergency rescue treatment. Mean age was 20 +8 (range 11 to 39) years and meanweight 48.6 +7 (39 - 60) kg. Variables measured wereregression of peak to peak systolic gradient and an increase in diameter of coarctationsite narrow point.RESULTS: 22 patients underwent implantation of Covered Cheatham Platinum (CP) stents from February 2010 to June 2019. There was significant reduction of mean systolic gradient from 42 +2 mmHg to 8 + 6 mm Hg (P< 0.0001). There was significant increase of mean diameter of coarctation narrow point from 3.9mm (+0.2) to14.9 mm (+ 1.7 mm).There was no death. No patient developed dissection or aneurysm formation when evaluated 24 hrs after the procedure. No patient had a stent migration or stent fracture. No case was abandoned or referred for surgery. Three patients had blood transfusion during the procedure due to bleeding while procedure. External iliac artery injury requiring immediate stenting was needed in one patient. Two patients had loss of lower limb pulses which was resolved successfully with anticoagulation by using heparin infusion. One patient had thrombus formation at right brachial artery requiring embolectomy by forgarty catheter with no residual loss. CONCLUSION: Covered Cheatham Platinum stents are safe and effective in the management of coarctation of the aorta in adolescents and adults. It is a feasible option in a resource-limited country where re-intervention and follow up are major issues. Long term result show ever, need to be in follow-up study
Publication Details
Page(s) 112-116
DOI DOI not available
Published Journal: Journal of Cardiovascular Diseases, Volume: 16, Issue: 3, Year: 2020

Request the full text from PASTIC

Keywords
Congenital heart disease, stent implantation, Coarctation of the aorta