No Detail Found!

Use of a chlorhexidine-impregnated dressing reduced catheter-related bloodstream infections caused by Gram-positive microorganisms.

Author(s)
Ayse Betul Ergul Department of Pediatrics, Intensive Care Unit, University of Health Sciences, Kayseri Training and Research hospital,Kocasinan, Kayseri, Turkey
Ikbal Gokcek Department of Pediatrics, Intensive Care Unit, University of Health Sciences, Kayseri Training and Research hospital,Kocasinan, Kayseri, Turkey
Alper Ozcan Department of Pediatrics, Intensive Care Unit, University of Health Sciences, Kayseri Training and Research hospital,Kocasinan, Kayseri, Turkey
Serife Cetin Department of Pediatrics, Intensive Care Unit, University of Health Sciences, Kayseri Training and Research hospital,Kocasinan, Kayseri, Turkey
Nurkan Gultekin Department of Infection Control, University of Health Sciences, Kayseri Training and Research Hospital, Kayseri, Turkey
Yasemin Altuner Torun University of Health Sciences, Kayseri Training and Research Hospital, Kayseri, Turkey
Abstract
Objective: We compared the protective effects of secure Chlorhexidine Gluconate (CHG)-containing dressings with those of non-antimicrobial transparent dressings. Methods: This prospective, comparative, single-center clinical study was conducted in a tertiary pediatric intensive care unit from October 2014 to March 2017. The inclusion criterion was catheterization of the jugular vein for =48 hour. The study was conducted in two phases. Non-antimicrobial standard dressings were applied both before and after the CHG- dressing phase to negate any coincidental temporal effect. During the standard-dressing phases, the dressings did not include any antimicrobial; transparent CHGimpregnated dressings were applied during the test phase. All patients were divided into two groups by the type of dressing applied (standard and CHG-containing dressings). Results: The standard- and CHG-dressing groups contained 68 and 63 patients, respectively. The median durations of catheterization were 13 (8-22) and 14 (2-28) days, respectively (p>0.05). The Catheter-Related Bloodstream Infection (CRBSI) rate was somewhat lower in the CHG-dressing group (20.6 vs. 26.5%), but the difference was not statistically significant (p>0.05). In the CHG-dressing group, CRBSIs caused by Grampositive microorganisms totaled 0%, but the figure was 8.8% in the control group ( p=0.028). Conclusions: CHG dressings reduced CRBSIs caused by Gram-positive microorganisms.
Publication Details
Page(s) 347-351
DOI DOI not available
Published Journal: Pakistan Journal of Medical Sciences, Volume: 34, Issue: 2, Year: 2018

Request the full text from PASTIC

Keywords
Catheter securement, Chlorhexidine dressing