Comparison of residual monomer leaching from orthodontic adhesives at different light curing tip distances.

Author(s)
Muhammad Azeem Faisalabad Medical University, Pakistan
Arfan Ul Haq Faisalabad Medical University, Pakistan
Farzana Ambreen de'Montmorency College of Dentistry Lahore, Pakistan
Waheed Ul Hamid de'Montmorency College of Dentistry Lahore, Pakistan
Salman Ghauri de'Montmorency College of Dentistry Lahore, Pakistan
Abstract
Introduction: Improving the bond strength of orthodontic adhesives along with reduction in their deleterious effects has always been required. Present study was aimed at comparing the mean residual monomer (RM) leaching from adhesives cured at 0mm and 10mm curing light tip distances. Material and Methods: In this in-vitro study, 60 extracted teeth were selected and 30 teeth were placed in group A and 30 teeth were placed in group B, by random process. Group A teeth brackets were cured at light tip distance of 0mm and Group B at 10mm distance. High performance liquid chromatography (HPLC) was utilized for measuring the RM. Independent t-test was used for comparison of mean release of RM. Results: The mean value of RM was significantly higher in adhesives cured at 10mm distance (p-value = 0.000). Conclusions: 0mm curing light tip distance is recommended in clinical orthodontic practice as the residual monomer leaching was significantly less as compared to the 10mm distance.
Publication Details
Page(s) 29-32
DOI DOI not available
Published Journal: Pakistan Orthodontic Journal, Volume: 11, Issue: 1, Year: 2019

Request the full text from PASTIC

Keywords
bisphenol A, curing light