No Detail Found!

Combination of Stop-bang Score and Mandibulohyoid Distance in the Prediction of Difficult Airway among Obstructive Sleep Apnea Patients.

Author(s)
Kok Tong Lee Department of Anesthesiology and Intensive Care, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia; Hospital Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
Rhendra Hardy Mohamad Zaini Department of Anesthesiology and Intensive Care, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia; Hospital Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
Wan Mohd Nazaruddin Wan Hassan Department of Anesthesiology and Intensive Care, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia; Hospital Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
Chandran Nadarajan Hospital Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia; Department of Radiology, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
Yee Cheng Kueh Biostatistic Unit, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
Mohamad Ibariyah Iberahim Department of Anesthesiology and Intensive Care, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia; Hospital Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
Lee Min Foo Hospital Raja Perempuan Zainab II, 15200 Kota Bharu, Kelantan, Malaysia
Soon Eu Chong 6Regenerative Medicine Cluster, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, Kepala Batas, Penang, Malaysia.
Abstract
Objective: This study was designed to evaluate the diagnostic performance of STOPBANG score and mandibulohyoid distance (MHD) towards difficult laryngoscopy among obstructive sleep apnea patients. Cross-Sectional Study Methodology: Forty-one patients who had STOP-BANG scores of >3 and required tracheal intubation for general anesthesia were recruited in this cross-sectional study. MHD was measured through lateral cephalometry. After induction of anesthesia, an anesthesiologist who was blinded to patient’s profile performed a laryngoscopy and evaluated the Cormack-Lehane grading. Sensitivity, specificity, positive and negative predictive values were determined for STOP-BANG and MHD. Binary logistic regression, receiver operating characteristics (ROC) and correlation analyses were employed. Results: Body mass index, neck circumference, and Mallampati scores were higher in the difficult laryngoscopy group. MHD was longer in difficult laryngoscopy group (25.40 ± 5.67 mm) than easy laryngoscopy group (20.17 ± 4.28 mm; p = 0.002). STOPBANG score was higher in difficult laryngoscopy group (5.86 ± 0.96 vs. 4.30 ± 0.98; p < 0.001). The combination of MHD and STOP-BANG score improved the quality of diagnostic test in predicting the laryngoscopy status with area under ROC of 87.6%, compared to each isolated parameter (i.e., MHD = 75.7%, STOP-BANG = 85.5%). Both MHD and STOP-BANG scores were significantly positive correlated (r = 0.42, p = 0.006). Conclusions: STOP-BANG score and MHD were useful in predicting difficult intubation. The diagnostic performance improved further when combining both parameters.
Publication Details
Page(s) 204-210
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 23, Issue: 2, Year: 2019

Request the full text from PASTIC

0

Citations

0

Downloads

54

Views