No Detail Found!

Effect of topical application of hard water in weakening of hair in men.

Author(s)
Muhammad Waqas Luqman Department of Biochemistry, Khyber Medical University, Institute of Basic Medical Sciences, KPK, Pakistan
Roshan Ali Department of Biochemistry, Khyber Medical University, Institute of Basic Medical Sciences, KPK, Pakistan
Zahid Khan Department of Biochemistry, Institute of Chemical Science, Peshawar, KPK, Pakistan
Muhammad Haris Ramzan Department of Physiology, Khyber Medical University, Institute of Basic Medical Sciences, KPK, Pakistan
Fazal Hanan Department of Microbiology, Lady Reading Hospital, Peshawar, Pakistan
Usama Javaid Hayatabad Medical Complex, Peshawar, KPK, Pakistan
Abstract
Background: Hard water is thought to play a key role in weakening of hair (not Hair Loss) and breakage especially when travelling is involved. In our community, commonly men do the travelling and complain more about hair problem which is why only young male individuals were included in this study. Materials and Methods: Water samples from different districts of KPK, Pakistan, were collected and their hardness values were estimated to find the water sample of maximum and minimum water hardness in order to know the maximum hardness hair would encounter in KPK, Pakistan. Samples from district Kohat had maximum hardness whereas minimum hardness was estimated in samples of district Peshawar. Water from district Kohat was considered as our sample water for the experimental group of hair. Hairsamples were collected from 76 male individuals of district Peshawar, the area with least water hardness among the samples collected. Each hair sample was divided into two halves. One half was considered as experimental group and the other was considered as control group. The experimental group was treated with hard water of district Kohat for 10 minutes on alternate days, for 3 months. In a very similar way the control group wastreated with de-ionized water. Tensile strength in term of "Stress" of both the experimental and control groups were measured using the universal testing machine and compared using paired t-test. Results and Conclusions: The standard deviations (SD) for hair treated with hard water and distilled water was 62.05 and 58.13 respectively and the mean values were 238.49 and 255.36 respectively. The results showed that the tensile strength of hair was significantly (p=0.001) reduced in hair treated with hard water as compared to hair treated with de-ionized water.
Publication Details
Page(s) 1132-1136
DOI DOI not available
Published Journal: Journal of Pakistan Medical Association, Volume: 66, Issue: 9, Year: 2016

Request the full text from PASTIC

0

Citations

0

Downloads

96

Views