The correlation study of 2 micron continuous wave laser between released laser energy and vaporized prostate tissue weights.

Author(s)
H. Guo Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
J. Li Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
H. Liu Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
G. Zhou Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
B. Sun Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
Z. Yao Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
D. Mu Department of Urology, General Hospital of the Air Force, PLA, Beijing, China
Abstract
Background and Objectives: To explore the effective method to calculate vaporized tissues during endo-scopic prostate surgery using a 2 micron continuous wave laser, by observing the association between vaporized canine prostate tissue weight and released laser energy in an ex-vivo study.The aim was also to assess the extent of thermal damage at different laser power and different modes. Methods: A total of 20 canine prostates were divided into four groups randomly. 2 micron continuous wave laser with output power of 40 W and 70 W was used to ablate tissues in vaporesection or vapo-rization mode. Vaporized canine prostate tissue weights were measured by recording the pre-and post-ablation sample weight. Results and Conclusions: With the increase of output power from 4o W to 70 W, ablation efficiency in the vaporesection mode decreased (P = o. 027, while the ablation efficiency increased in the vapori-zation mode (P = o. ow). Our data showed a linear relationship between vaporized prostate tissue wei-ghts and released laser energy (Pearson correlation coefficient r = o. 8689 P = o. ow) at 70 W output power. Therefore, the amount of prostatic tissues vaporized by 2 micron continuous wave lasers could be calculated from the released laser energy through the linear relationship between vaporized prostate tissue weights and released laser energy. Under the same operating mode there were no significant dif-ferences in corresponding depths of coagulation zone. Under the same output power, vaporization pro-duced a significantly deeper coagulation zone than that produced by vaporesection (P
Publication Details
Page(s) 199-203
DOI DOI not available
Published Journal: Biomedica, Volume: 31, Issue: 3, Year: 2015