No Detail Found!

Parameters Calculations of Transformer and its Performance Analysis under Transients.

Author(s)
Muhammad Tariq Sadiq Department of Electrical Engineering, Sharif College of Engineering and Technology Lahore, Pakistan
Muhammad Fraz Khalid Department of Electrical Engineering, Sharif College of Engineering and Technology Lahore, Pakistan
Muhammad Umair Abid Department of Electrical Engineering, Sharif College of Engineering and Technology Lahore, Pakistan
Abstract
During this study, a high frequency model of transformer is proposed which is capable of eliminating the effects of transients applied on transformer. The conventional transformers use surge arrestors to remove these kind of effects, but they also transfers the effects of transients on secondary side which are hazardous for electrical equipment's. Our proposed model is capable of eliminating the effects of transients without any major change in secondary voltage. This method is based on two-port network (T model) theory. The results of our method are examined and evaluated by computer simulations based on MATLAB.
Publication Details
Page(s) 92-95
DOI DOI not available
Published Journal: Journal of Applied and Emerging Sciences , Volume: 6, Issue: 2, Year: 2016

Request the full text from PASTIC

References
Ÿ McNuttWJ,BlalockTJ,HintonRA., 1973., -
Okabe S, Koutou M, Teranishi T, Takeda S and Saida T. (2001). A high frequency model of an oil-immersed transformer, and its use in lightning surge analysis. Elect. Eng. Jpn. 134(1): 28–35
Ÿ Shibuya Y and Fujita S. (2004). High frequency model of transformer winding,” Elect. Eng. Jpn. 146(3): 8–16
SmithDR,PuriJL.,- 1936 Ÿ BiernackiJ,CzarkowskiD., 2001.High frequency transformer modelling,Proc. IEEE Int. 4 1927 -16
Symp, .,Circuits and Systems 3 676 -679
FujitaS., 2002.High frequency model and transient response of transformer windings,Proc. IEEE Power Eng. Soc. -
Transmission and Distribution,Conf, .,Asia Pacific 3 1839 -1844
Ÿ VaessenPTM.,MorchedAL,Marti Ottevangers, 1993.A high frequency transformer model for EMTP.,IEEE Transactions on Power Delivery 4 1761 -1768
BachegaRJ,PivattoJKA,MartinezMLB., .,IEEE Transactions on Power Delivery 3 1615 -1626
205P.Contribution to the study of lightning induced voltages on distribution lines (in Portuguese),MSc Thesis 01 -04
Ÿ PiantiniA,BassiW,JaniszewskiJM,MatsuoN., 1999.A single transformer model for analysis of lightning surges transferred from MV to LV lines,Proceedings of 15th International Conference on Electric Distribution (CIRED 15th) -
Ÿ SabihaNA,LehtonenM., 2009., -
Lightning Induced Overvoltages Transmitted Over Distribution Transformer With MV Spark-Gap Operation-Part I: High Frequency Transformer Model,IEEE Transactions on Power Delivery 25 2472 -2480-2010
Sabiha NA and Lehtonen M. (2009). Experimental verification of distribution transformer model under lightning strokes. Presented at the IEEE Power Eng. Soc. Power syst. Conf. Expo., Seattle, WA
Nehmdoh A, Sabiha and Matti Lehtonen. (2010). Lightning Induced Overvoltages Transmitted Over Distribution Transformer With MV Spark-Gap Operation-Part I: High Frequency Transformer Model. IEEE Transactions on Power Delivery 25(4):2472- 2480
0

Citations

0

Downloads

90

Views