No Detail Found!

Design and Fabrication of Alternative Cooling System for Conventional Purpose.

Author(s)
N Yogaraj Department of Mechanical Engineering, VSB Engineering College, Karur, India
P Ganeshan Department of Mechanical Engineering, VSB Engineering College, Karur, India
P Raju Department of Mechanical Engineering, VSB Engineering College, Karur, India
PANigal Ashik Department of Mechanical Engineering, VSB Engineering College, Karur, India
B Boobalan Department of Mechanical Engineering, VSB Engineering College, Karur, India
K Arumugam Department of Mechanical Engineering, VSB Engineering College, Karur, India
DDinesh Kumar Department of Mechanical Engineering, VSB Engineering College, Karur, India
V Logeshwaran Department of Mechanical Engineering, VSB Engineering College, Karur, India
K Raja Department of Mechanical Engineering, Anna University, Dindigul 624 622, India
Abstract
The main purpose of this alternate cooling system is to circulate cooling air to the surrounding that means it will act as an air cooling system. Instead of using water, ice cubes are used here. The exhaust fan plays a main purpose of the exhaust fan is to suck the air from the closed area (polystyrene container) and supply to surrounding. The polystyrene box is nothing but the thermocol container and it is shaped into required dimensions for fitting the exhaust fan at the center of the box. The sufficient ice cubes are kept inside the box. Once the ice bars are filled into the closed container the vapour arises, after completing all the setting process the exhaust fan is switched to ON position, so that it exhausts the vapour to the surrounding. The cooling capacity is measured with the help of digital thermometer and the temperature is to be noted for every 2 hours so that the verification of the cooling capacity is to be done.
Publication Details
Page(s) 47-50
DOI DOI not available
Published Journal: Pakistan Journal of Biotechnology, Volume: 15, Issue: S1, Year: 2018

Request the full text from PASTIC

References
Alosaimy , A.S., 2013.Application of Evaporative Air Coolers Coupled with Solar Water Heater for Dehumidification of Indoor Air,International Journal of Mechanical & Mechatronic Engineering 13 60 -68
Antunes , A.H.P.,F.P., 2016.BandarraFilho, Experimental investigation on the performance and global environmental impact of a refrigeration system retrofitted with alternative refrigerants,International Journal of Refrigeration 70 119 -127
Chandrasekaran , K.,P.Marimuthu,K.Raja, 2013.Prediction model for CNC turning on AISI316 with single and multilayered cutting tool using Box Behnken Design,International Journal of Engineering Transactions A: Basics 26 621 -630
Dharmalingam , S.,P.Marimuthu,K.Raja, 2014.Optimum Setting of Drilling Parameters in Electrochemical Micro Machining Using Grey Relational Analysis,Latin American Applied Research 44 331 -338
Elgendy , E.,M.Hassanain,M.Fatouh, 2014.Assessment of R-438A as a retrofit refrigerant for R-22 in direct expansion water chiller,Int. J. Refrig 50 127 -136
Farhan , A.K., 2012.Improving the environmental cooling for air-coolers by using the indirect-cooling method,ARPN Journal of Engineering and Applied Sciences 5 66 -73
Ganeshan , P.,K.Raja, 2016.Improvement on the Mechanical Properties of Madar Fiber Reinforced Polyester Composites,Int J AdvEngg Tech 7 261 -264
Ganeshan , P.,K.Raja,K.Lingadurai,M.Kaliappan, 2015.Design and Development Of Alternate Composite Material For An Automobile Drive Shaft,International Journal of Applied Engineering Research 10 12051 -12057
Porto , M.,R.Koury,L.Machado, 2013.An alternative method to estimate refrigeration system inventory,Applied Thermal Engineering 52 313 -320
Rocca , V.L.,G. Panno,, 2011.Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants,Applied Energy 88 2809 -2815
SenthilRajan , A., K.,Raja and P.,Marimuthu, 2014., Multi basin desalination using biomass heat source and analytical validation using RSM,Energy Conversion and Management 87 359 -366
Teng , T.P.,H.E.Mo,H.Lin,Y.H.Tseng,R.H.Liu,Y.F.Long, 2012.Retrofit assessment of window air conditioner,Appl. Therm. Eng 32 100 -107
0

Citations

0

Downloads

54

Views