No Detail Found!

Indoor Air Quality (IAQ) Characteristics and its Microbial Community Identifications at Two Selected Schools in Pahang, Malaysia: a Preliminary Study.

Author(s)
Hizrri A Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Zati Nabilah MG Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Nurul Amni Z Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Shahida N Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Maryam Z Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Hazrin AH Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Mohd Faez S Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Mohd Shukri MA Department of Biotechnology, Kulliyyah of Science, International Islamic University Malaysia, Kuantan Campus, Pahang, Malaysia
Abstract
It is important to assess IAQ characteristics and to identify possible microbial contaminants in schools' indoor environment because children are more vulnerable to air pollutants as they inhale more air pollutants per kilograms of body weight. Hence, this study aims to assess and to compare the level of selected IAQ parameters and microbiological contaminants inside the classroom of schools in urban area and rural area during occupied and non-occupied period. This study also aims to identify airborne bacteria species and fungi genera within classroom of schools in those area. For methodology of the study, schools were selected based on their location. School X (SX) was located in Kuantan, Pahang, while school Y (SY) was located in Pekan, Pahang. The physical IAQ parameters (Temperature, Relative Humidity (RH), Carbon Dioxide (CO2) were measured using VelociCalc® Multi-Function Ventilation Meter 9565 (TSI®, Minnesota, USA), and airborne particulate matter (PM) were measured using DustMate (Turnkey Instruments, UK). Surface Air System Indoor Air Quality (SAS IAQ), (PBI International, Italy) was used to collect the microbial contaminants and subsequently CFU were counted. The data were recorded for 30 minutes for each timeslot for 8 hours during occupied and non-occupied period within selected classrooms. Bacteria identification was done using 16S rRNA gene sequence analysis and fungi were identified macroscopically through direct identification technique up to genus level. The results were compared to standard reference limit based on Industrial Code of Practice on Indoor Air Quality (ICOP, 2010) regulated by the Department of Occupational Safety and Health (DOSH, 2005). This study found that temperature (SX, Occupied; 34.9±3.9, Non-Occupied; 32.8±0.7), (SY, Occupied; 30.7±0.2, NonOccupied; 30.6±0.5), RH (SY, Occupied; 74.4±2.9, Non-Ocupied; 70.05±1.0) and bacterial CFU counts (SX, Occupied; 558±308), (SY; Occupied; 903±415, NonOccupied; 1176±303) exceeded the standard limit regulated by DOSH. Number of gram-negative bacteria dominated over gram-positive bacteria in both settings. Bacillus sp. (B. atrophaeus, B. subtilis, B. pumilus, B. altitudinis. B. tequilensis, and B. aerophilus) were the most dominant species, followed by Staphylococcus sp. (S. warneri, S. sciuri, S. haemolyticus, and S. gallinarum). The common fungal species isolated in both schools during occupied and non-occupied period were Aspergillus, Alternaria, Cladosporium, Penicillium, and Mucor.
Publication Details
Page(s) 88-96
DOI DOI not available
Published Journal: Asian Journal of Agriculture and Biology, Volume: 0, Issue: S1, Year: 2018

Request the full text from PASTIC

Keywords
bacteria, Schools, fungi
References
Almeida , S.M.,Canha , N.,Silva , A.,M.C.Freitas,P.Pegas,C.Alves,M.Evtyugina,C.A.Pio, 2011.Children exposure to atmospheric particles in indoor of Lisbon primary schools,Atmospheric Environment 45 7594 -7599
Alves , C.,Duarte , M.,Ferreira , M.,Alves , A.,Almeida , A.,Cunha , A., 2015.Air quality in a school with dampness and mould problems, -
Alves , C.,Nunes , T.,Silva , J.,Duarte , M., 2013.Comfort parameters and particulate matter (PM10 AND PM2.5) in school classrooms and outdoor air,Aerosol and Air Quality Research 13 1521 -1535
Bornehag , C. G.,Blomquist , G.,Gyntelberg , F.,Jarvholm , B.,Malmberg , P.,Nordvall , L.,Sundell , J., 2001.Dampness in buildings and health,Indoor Air 11 72 -86
Chen , S.,Wang , Y.,Chen , F.,Yang , H.,Gan , M.,Zheng , S. J., 2007.A highly pathogenic strain of Staphylococcus Sciuri caused fatal exudative epidermitis in piglets,PLOS ONE 2 147 -
Chua , P. C.,Juliana , J.,Titi , R. H.,Nor , M. A., 2015.Indoor air quality assessment and lung functions among children in preschool at Selangor, Malaysia,Advances in Environmental Biology 9 1 -9
D'Arcy , N.,Canales , M.,Spratt , D. A.,Lai , K., 2012.Healthy schools: standardization of culturing methods for seeking airborne pathogens in bioaerosols emitted from human sources,International Journal of Aerobiology. -
Devriese , L. A.,PoutrelB,Kilpper-BalzR,SchleiferK H., 1983.Staphylococcus gallinarum and Staphylococcus caprae, two new species from animals,International Journal System Bacteriology 33 480 -486
Emilia , Z. A.,Sean , S.,Irniza , R.,Sharifah , N.,Syed , I.,Jon , G.,A., 2014.The relationship between air pollution and asthma in Malaysian school children,Air Quality Atmospheric Health. 7 421 -432
EPA-Environmental Protection Agency,ThirdEdition, 2005.IAQ reference guide. tools for schools, EPA 402-, -
Fischer , E. M.,Oleson , K. W.,Lawrence , D. M., 2012.Contrasting urban and rural heat stress responses to climate change,Geophysical Research Letters 39 L03705 -
Gatson J. W. , Benz,B.F. , Chandrasekaran,C. , Satomi,M. , Venkateswaran,K. , and Hart,M. E., 2000.- year-old Mexican shafttomb, is closely related to Bacillus subtilis,International Journal System Evolutionary Microbiology 56 1475 -84
Hauschild , T.,Schwarz , S., 2003.Differentiation of Staphylococcus Sciuri strains isolated from freeliving rodents and insectivores,Journal Veterinary Medicine B Infect Dis Vet Public Health 50 241 -6
Hormazabal , V.,Granum , P.E., 2007.Food poisoning associated with pumilacidin producing Bacillus pumilus in rice,International Journal Food Microbiology 115 319 -24
Hu , Y.,Zhang , J.,Li , X.,Yang , Y.,Zhang , Y.,Ma , J.,Xi , L., 2013.Penicillium marneffei infection: an emerging disease in mainland China,Mycopathologia 175 57 -67
Hurtado , L.,Rodriguez , G.,Lopez , J.,Castillo , J. E.,Molina , L.,Zavala , M.,Quintana , P. J. E., 2014.Characterization of atmospheric bioaerosols at 9 sites in Tijuana, Mexico,Atmospheric Environment 96 430 -436
Hussin , N. H. M.,Sann , L. M.,Shamsudin , M. N.,Hashim , Z., 2011.Characterization of bacteria and fungi bioaerosol in the indoor air of selected primary schools in Malaysia,Indoor and Built Environment 20 607 -617
Incani , R. N.,Hernández , M.,Cortez , J.,González , M. E.,Salazar , Y. D., 2010.CASE REPORT Staphylococcus warneri: Meningitis in a patient with Strongyloides Stercoralis Hyperinfection and Lymphoma,Revised Institute Medical Trop. Sao Paulo 52 169 -170
Ismail , M. N.,Sofian , Z.M.,Abdullah , A.M., 2010.Indoor air quality in selected samples of primary schools in Kuala Terengganu, Malaysia,Environment Asia 3 103 -108
Khusro , A.,Aarti , C.,Preetamraj , J. P.,Panicker , S. G., 2013.In vitro Studies on antibacterial activity of aqueous extracts of spices and vegetables against Bacillus licheniformis strain 018 and Bacillus tequilensis strain ARMATI,International Journal Current. Microbiology.Applied Science 2 79 -88
Kloos , W. E.,Bannerman , T. L., 1994.Update on clinical significance of coagulase-negative staphylococci,Clinical Microbiology Revised. 7 117 -140
Kobayashi , T.,Iijima , K.,Radhakrishnan , S.,Mehta , V.,Vassallo , R.,C. B. , & Kita,H., 2009.Asthma-related environmental fungus, Alternaria, activates dendritic cells and produces potent Th2 adjuvant activity,The Journal of Immunology 182 2502 -2510
Lee , S. C.,Chang , M., 2000.Indoor and outdoor air quality investigation at schools in Hong Kong,Chemosphere 41 109 -113
Liu , L. J.,Krahmer , M.,Fox , A.,Feigley , C. E.,Featherstone , A.,Saraf , A.,Larsson , L., 2000.Investigation of the concentration of bacteria and their cell envelope components in indoor air in two elementary schools,Journal Air Waste Management Association 50 1957 -1967
Lugauskas , A.,Levinskaite , L.,Peciulyte , D., 2003.Micromycetes as deterioration agents of polymeric materials,International Biodeterioration 52 233 -242
Lund , B. M., 1990.Foodborne diseases due to Bacillus and Clostridium species,Lancet 336 982 -986
Meklin , T,T. , Pekkanen,J. , Hyvrinen,A. , Hirvonen,M. R. , Nevalainen,A., 2005.Effects of moisture-damage repairs on microbial exposure and symptoms in school children,Indoor Air; 15 (Suppl 10 40 -47
Meklin , T.,Husman , T.,Vepsäläinen , A.,Vahteristo , M.,Koivisto , J.,Hyvärinen , A.,Moschandreas , D.,Nevalainen , A., 2002.Indoor air microbes and respiratory symptoms of children in moisture damaged and reference schools,Indoor Air 12 175 -183
Mohai , P.,Kweon , B. S.,Lee , S.,Ard , K., 2011.Air pollution around schools is linked to poorer student health and academic performance,Health Affairs 30 852 -862
NurAida,A.,J.Jalaludin,A.B.Suhaili, 2014.Indoor air pollutants exposure and the respiratory inflammation (FeNO) among preschool children in Hulu Langat, Selangor,Advances in Environmental Biology 8 164 -170
NurAzwani,M. N. R. , Juliana,J. , and Poh,C. C., 2015.Indoor Air Quality and respiratory health among malay preschool children in Selangor,BioMed Research International. volume Article ID 248178 -
Oke , T., 1987.Boundary Layer Climates, 2nd edition, -
Pegas , P. N., 2012.Indoor air quality in elementary schools of Lisbon and Aveiro,PhD Thesis -
Pegas , P. N.,Alves , C. A.,Evtyugina , M. G.,Nunes , T.,Cerqueira , M.,Franchi , M.,Pio , C.A.,Almeida , S. M.,Freitas , M. C., 2011.Indoor air quality in elementary schools of Lisbon in spring, -
Ralph A. S.,H. Ernest Hemphill., 2006.,The Genus Bacillus-Nonmedical Prokaryotes 4 530 -562
Rampal , L.,Jegathesan , M.,Lim , Y.S., 1984.An outbreak of Bacillus cereus food poisoning in a school hostel,Klang. The Medical Journal of Malaysia 39 116 -122
Ribes , J. A.,Vanover-Sams , C. L.,Baker , D. J., 2000.Zygomycetes in human disease,Clinical Microbiology Reviews 13 236 -301
Rosenkvist H. , and Hansen,Å ., 1995.Contamination profiles and characterization of Bacillus species in wheat bread and raw materials for bread production,International Journal of Food Microbiology 26 353 -363
Rusul G. , and Yaacob,N. H., 1995.Prevalence of Bacillus cereus in selected foods and detection of enterotoxin using TECRA-VIA and BCETRPLA,International Journal of Food Microbiology 25 131 -139
Samson , R. A.,Hoekstra , E. S.,Frisvad , J. C.,Filtenborg , O., 2000.Introduction to food and airborne fungi,Utrecht: CBS -
Sandra , A.,Afsah-Hejri , L.,Tunung , R.,TuanZainazor,T. C. , Tang,J. Y. H. , Ghazali,F.M. , Nakaguchi,Y. , Nishibuchi,R., 2012.Bacillus cereus and Bacillus thuringiensis in ready-to-eat cooked rice in Malaysia,International Food Research Journal 19 829 -836
Schaberg , D. R.,D. H.Culver,R. P.Gaynes., 3B.Major trends in the microbial etiology of nosocomial infection,Am. Journal Medical 91 72 -75
Shelton , B. G.,Kirkland , K. H.,Flanders , W. D.,Morris , G. K., 2002.Profiles of airborne fungi in buildings and outdoor environments in the United States,Applied and Environmental Microbiology 68 1743 -1753
Shivaji , S.,Chaturvedi , P.,Suresh , K.,Reddy , G. S. N.,Dutt , C. B. S.,Wainwright , M.,NarlikarJ. V.,Bhargava , P. M., 2006.Bacillus stratosphericus sp. nov. and Bacillus altitudinis sp. nov., isolated from cryogenic tubes used for collecting air samples from high altitudes,International Journal of Systematic and Evolutionary Microbiology 56 1465 -1473
SrdjanStepanović,PetrPetráš,Devriese, 2005.Identification and characterization of clinical isolates of members of the Staphylococcus sciuri Group,Journal Clinical Microbiology 43 956 -958
te Giffel , M. C.,Beumer , R. R.,Leijendekkers , S.,Rombouts , F. M., 1996.Incidence of Bacillus cereus and Bacillus subtilis in foods in Netherlands,Food Microbiology 13 53 -58
US., 1995.Indoor air quality basics for schools.,Environmental Protection Agency (USEPA) -
Wang , Y.F.,Huang , K.L.,Li , C.T.,Mi , H.H.,Luo , J.H.,Tsai , P.J., 2003.Emissions of fuel metals content from a diesel vehicle engine,Atmospheric Environment 37 4637 -4643
0

Citations

0

Downloads

26

Views