No Detail Found!

Concentration of 188Re-perrhenate for therapeutic radiopharmaceuticals.

Author(s)
Tanveer Hussain Bokhari Department of Chemistry, Government College University, Faisalabad, Pakistan
Saira Hina Department of Bioinformatics and Biotechnology, Government College University, Faisalabad, Pakistan
Mushtaq Ahmad Isotope Production Division, Pakistan Institute of Nuclear Science and Technology, Islamabad, Pakistan
Munawar Iqbal Department of Chemistry and Biochemistry, University of Agriculture Faisalabad, Pakistan
Muhammad Shafiq Department of Chemistry, Government College University, Faisalabad, Pakistan
Muhammad Nadeem Arshad Chemistry Department & Centre of Excellence for Advanced Materials Research, King Abdulaziz University, Saudia Arabia
Muhammad Nadeem Asghar Department of Chemistry, Forman Christian College University, Lahore, Pakistan
Muhammad Aslam Pharmaceutical Research Centre, PCSIR Labs Complex, Karachi, Pakistan
Asim Mansha Department of Chemistry, Government College University, Faisalabad, Pakistan
Muhammad Imran Qadir College of Pharmacy, Government College University, Faisalabad, Pakistan
Ijaz Ahmad Khan Department of Physics, Government College University, Faisalabad, Pakistan
Abstract
Rhenium-188 (T1/2=16.9h) has great potential for a variety of therapeutic applications, including radionuclide synovectomy, oncology and bone pain palliation. The radioactive concentration of 188Re is dependent upon the specific activity of 188W, which dictates the bed size of the alumina/gel column. Due to the high content of inactive tungsten in neutron irradiated WO3, large columns containing aluminum oxide or gel are needed to prepare to double neutron capture based 188W/188Re generators that results in large elution volumes containing relatively high188W contents and low concentrations of188ReO4-. This decrease in specific volume of 188ReO4-places a limitation because a high radioactive concentration of 188ReO4- is always needed for filling angioplasty balloons or other therapeutic radiopharmaceuticals like188Re -EHDP 188Re -EDTMP, 188Re –MAG3 and 188Re -DTPA. We report post elution concentration of 188ReO4-using in- house prepared lead cation exchange and alumina columns. Using these columns high bolus volume (10 mL saline) of 188ReO4-can conveniently be concentrated in 1 mL of physiological saline for therapeutic use.