Abstract
Background: Laryngoscopy and intubation is known to produce an exaggerated stress response. The aim in general anesthesia is to attenuate this stress response.Method: This was a prospective, randomized, and a single blindedstudy. Ethical committee approval was obtained and 100 patients, aged 20-50 years, ASA grade I and II of either gender undergoing elective surgery under general anesthesia at a tertiary care center in India between 2015 and 2016 were recruited. We compared the Macintosh and McCoy laryngoscope blades regarding intubation time, laryngoscopic view and hemodynamic variables.Results: Both groups were comparable regarding age, gender, height and baseline vitals.Patients intubated with McCoy blade showed no or minimal change in heart rate and mean arterial pressure as compared to Macintosh blade. The intubation time was comparable in both groups.Conclusion: McCoy blade was better in attenuating the stress response to laryngoscopy and tracheal intubation
Publication Details
Page(s) 193-198
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 22, Issue: 2, Year: 2018

Request the full text from PASTIC

Keywords
Laryngoscopy, Stress Response, McCoy blade, Intubating conditions
References
1977., 56 618 -21
Anaesth, 1987., 59 295 -9
ActaAnaesthesiol Scand, 1991., 35 442 -
., -
1995., 50 943 -6
1996., 51 977 -980
1996., 43 219 -
., -
1993., 48 516 -
2012.McCoy versus Macintosh laryngoscope,Saudi JAnesth 20 73 -7
TewariP,GuptaD,KumarA,SinghU, 2005.Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: The comparison of hemodynamic changes with Macintosh blade in a randomized trial,J Postgrad Med 51 260 -4
NishiyamaT,HigashizawaT,BitoH,KonishiA,SakaiT.,Macintosh, 1997.Which laryngoscope is the most stressful in laryngoscopy-,Miller or McCoy? Masui 46 1519 -24
HanTS,KinJA,ParkNG,LeeSM,ChoHs,Chung IS, 1999.A comparison of the effects of different type of laryngoscope on hemodynamics. McCoy versus the Macintosh blade,Korean J Anesthesiol 37 398 -41
SinghalS, 2007.Haemodynamic response to laryngoscopy and intubation: comparisonof McCoy And MacintoshLaryngoscope,The Internet Journal of Anesthesiology 17 1 -5
RomanJ,Beltrande HerediaB,GarciaVelascoP,ParramonF,GarciaR,VilaplanaJ, 1996.Hemodynamic response to intubation with Macintosh andMcCoyblades,Rev EspAnestesiolReanim 43 177 -9
HaidryMA,KhanFA, 2013.Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes. J A n a e s t h e s i o l C l i n P h a r m a c o l, 10 111710 -9185
BilginH,BozkurtM., 2006.Tracheal intubation using the ILMA, C-Trach or McCoy laryngoscope in patients with simulated cervical spine injury,Anesthesia 61 685 -91
BhartiN,AroraS,PandaNB, 2014.Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine,Saudi JAnesth 10 1658 -354X
GillYS,LeeGY,ChungRK,KimDY,KangSY, 2005.Effect of laryngoscopic and tracheal intubation duration on hemodynamic response during anesthetic induction withthiopental, fentanyl and rocuronium,Korean J Anesthesiol 49 147 -51
GillN,PurohitS,KalraP,LallT,KhareA, 2015.Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine,Anesth Essays Res 10 0259 -1162
VasudevanA,VenkatR,BadheAS, 2010.Optimal external laryngeal manipulation versus MCCoy blade in active position in patients with poor view of glottis on direct laryngoscopy,Indian JAnaesth 10 0019 -5049
LeonO,BenhamouD., 1998.Improvement of glottis visualisation with a Mccoy blade,Ann Fr AnesthReanim 17 68 -71
0

Citations

0

Downloads

38

Views