Processed Eeg and Non-invasive Cerebral Oximetry (Cerebral rSO2)Monitoring in Transcatheter Aortic Valve Implantation.

Author(s)
Marija Raquel Caetano Anesthesiology and Emergency Departments, Porto, Portugal
Ana Luisa Veiga De Sa Centro Hospitalar do Porto, Dept. of Anaesthesiology, Critical Care & Emergency Medicine, Porto, Portugal
Joana Barrcuo Moreira Centro Hospitalar do Porto, Dept. of Anaesthesiology, Critical Care & Emergency Medicine, Porto, Portugal
Manuel Antsuzo F Traila Campos Centro Hospitalar do Porto, Dept. of Anaesthesiology, Critical Care & Emergency Medicine, Porto, Portugal
Abstract
Transcatheter aortic-valve implantation (TAVI) has been suggested as a less invasive treatment for high-risk patients with aortic stenosis. Ischemic events remain a troublesome risk following TAVI. The use of neuromonitoring with cerebral rSO2 and Processed EEG may contribute to detect and correct imbalances in the oxygen demandto-delivery ratio. We describe two clinical cases of TAVI procedure-related complications with cerebrovascular repercussions that reflected on cerebral oximetry and electrical activity as detected by NIRS and processed EEG. Cerebral rSO2 and processed raw EEG monitoring is relevant and useful in this setting, enabling clinicians to identify and possibly take preventive/corrective actions on the peri-operative setting, in order to minimize secondary damage due to ischemic/hypoxic events.
Publication Details
Page(s) 105-108
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 22, Issue: 1, Year: 2018

Request the full text from PASTIC

References
BloomsteinLZ,GielchinskyI,BernsteinAD,ParsonnetV,SaundersC,KaranamR, 2001.Aortic valve replacement in geriatric patients: determinants of in-hospital mortality,Ann Thorac Surg 71 597 -600
Carnero-AlcazaM,MarotoLC,Cobiella-CarnicerJ,VilacostaI,Nombela-FrancoL,AlswiesA, 2017.Transcatheter versus surgical aortic valve replacement in moderate and high-risk patients: a metaanalysis,Eur J Cardiothorac Surg 10 644 -652
LeonMB,SmithCR,MackMJ,MakkarRR,SvenssonLG,KodaliSK, 2016.Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients,N Engl J Med 10 1609 -20
PagnesiM,MartinoEA,ChiaritoM,MangieriA,JabbourRJ,Van MieghemNM, 2016.Silent cerebral injury after transcatheter aortic valve implantation and the preventive role of embolic protection devices: A systematic review and meta-analysis,Int J Cardiol 221 97 -106
AlassarA,SoppaG,EdsellM,RichP,RoyD,Chis SterI, 2014.Incidence and mechanisms of cerebral ischemia after transcatheter aortic valve implantation compared with surgical aortic valve replacement,Ann Thorac Surg 09 802 -8