No Detail Found!

Evaluation of a Low-cost Videolaryngoscope - a Randomized Controlled Pilot Study.

Author(s)
Prasanna Vadhanan Department of Anesthesiology, Indira Gandhi Medical College & Research Centre, Puducherry, India
Kiruthika Balakrishnan Department of Anesthesiology, Indira Gandhi Medical College & Research Centre, Puducherry, India
Debendra Kumar Tripaty Department of Anesthesiology, Indira Gandhi Medical College & Research Centre, Puducherry, India
Abstract
Introduction: Endotracheal intubation is one of the fundamental skills that should be mastered by the anesthesiologist. One of the important causes of anesthesia related mortality and morbidity is airway related events. Several video laryngoscopes are available in the market to facilitate intubation both in and out of the hospital scenarios. These devices are precluded by their cost and availability especially in developing countries. In this pilot study we have evaluated a custom made low-cost straight blade video laryngoscope (v-scope) which can be attached to a smartphone, compared to a conventional Miller blade with regards to time taken for intubation, when performed by trainee anesthesiologists. Ours is the first low cost laryngoscope that is based on a tsraight blade design. Methodology: Forty adult patients posted for elective surgeries under general anesthesia were randomized into groups of twenty each. Patients of the first group were intubated with the aid of a Millers blade and bougie using a paraglossal technique. The other group was intubated with a low-cost video laryngoscope (v-scope) under similar conditions. All intubations were performed by trainee anesthesiologists. The primary objective was the time taken for intubation. The time taken for visualization of glottis (t1), further time taken for successful passing of endotracheal intubation (t2) were also noted. The ease of intubation, use of additional maneuvers, hemodynamic response and any adverse events were also noted. Results: The time taken for intubation was similar in both groups (77.25 ± 26.46 vs 74.15 ± 26.3 sec, mean ± SD). The glottis view was better and need for external laryngeal manipulation was lesser with the v-scope. The time taken from visualization of the glottis to intubation was prolonged in the v-scope group (21.1 ± 6.1 sec vs 14.7 ± 3.6 sec, p< 0.001). No significant adverse events were observed Conclusion: The low-cost video laryngoscope is a useful device in the hands of trainees that can improve the glottic views and achieve similar intubation times as compared to Miller's blade, similar to other video laryngoscopes.
Publication Details
Page(s) 406-412
DOI DOI not available
Published Journal: Anaesthesia, Pain and Intensive Care, Volume: 21, Issue: 4, Year: 2017

Request the full text from PASTIC

References
GreenlandKB,EdwardsMJ,HuttonNJ,ChallisVJ,IrwinMG,SleighJW, 2010.Changes in airway configuration with different head and neck positions using magnetic resonance imaging of normal airways: a new concept with possible clinical applications,Br J Anaesth 105 683 -690
NiforopoulouP,PantazopoulosI,DemestihaT,KoudounaE,XanthosT, .Video-laryngoscopes in the adult airway management: A topical review of the literature,Acta Anaesthesiol Scand 54 1050 -61
PrasanaV.,KarippacehrilJG,Le Cong M., 2016.Videolaryngoscopy using an Android smartphone: A direct digital technique,Ind J Anaesth 60 143 -145
SunDA,WarrinerCB,ParsonsDG,KleinR,UmedalyHS,MoultM., 2005.The GlideScope Video Laryngoscope: randomized clinical trial in 200 patients Br, 94 381 -4
GriesdaleD,LiuD,McKinneyJ,ChoiPT, 2012.Glidescope video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis,Can J Anesth 10 41 -52
YousefGT,AbdalgalilDA,IbrahimTH, 2012.Orotracheal intubation of morbidly obese patients, comparison of GlideScope® video laryngoscope and the LMA C-TrachTM with direct laryngoscopy,Anesth Essays Res 10 108304 -1162
NgI,HillAL,WilliamsDL,LeeK,SegalR, 2012.Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways,Br J Anaesth 10 439 -443
HendersonJJ, .The use of paraglossal straight blade laryngoscopy in difficult tracheal intubation,Anaesthesia 52 552 -60
SzarpakL,TruszewskiK,CzyzewskiL,GaszynskiT, 2015.RodriguezNune A. A comparison of the McGrath-MAC and Macintosh laryngoscopes for child tracheal intubation during resuscitation by paramedics. A randomized, crossover, manikin study,Am J Emerg Med 11 1338 -41
SarginM,UluerMS, 2016.Comparison of McGrath® Series 5 video laryngoscope with Macintosh laryngoscope: A prospective, randomised trial in patients with normal airways,Pak J Med Sci 10 869 -874
NgI,SimXL,WilliamsD,SegalR., 2011.A randomised controlled trial comparing the McGrath® videolaryngoscope with the straight blade laryngoscope when used in adult patients with potential difficult airways,Anesthesia 06767 2044 -714
HealyDW,PictonP,MorrisM,TurnerC, .Comparison of the glidescope, CMAC, storz DCI with the Macintosh laryngoscope during simulated difficult laryngoscopy: a manikin study,2012 Jun 21 11 -
BurdettE,Ross-AndersonDJ,MakepeaceJ,BassettPA,ClarkSG,MitchelV, 2011.Randomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study,Br J Anaesth 10 983 -988
Liu Z-J , Yi J,GuoW-J,MaC,HuangY-G, 2016.Comparison of McGrath Series 3 and Macintosh laryngoscopes for tracheal intubation in patients with normal airway by inexperienced anesthetists: a randomized study,Medicine (Baltimore) 10 -
0

Citations

0

Downloads

57

Views