Pakistan Science Abstracts
Article details & metrics
No Detail Found!!
Accuracy of Working Length Measured by Apex Locator and Digital Radiography
Author(s):
1. Ghulam Ishaq Khan: Department of Operative Dentistry, Bacha Khan Dental College, Mardan, Pakistan.
2. Muhammad Talha Khan: Department of Operative Dentistry, Fatima Memorial Hospital, Lahore, Pakistan.
3. Saroosh Ehsan: Department of Operative Dentistry, Fatima Memorial Hospital, Lahore, Pakistan.
4. Anam Fayyaz: Department of Operative Dentistry, Lahore Medical and Dental College, Lahore. Pakistan
5. Haider Amin Malik: Department of Prosthodontics, Fatima Memorial Hospital, Lahore, Pakistan.
6. Shafqat Hussain: Department of Prosthodontics, Rehman College of Dentistry, Peshawar, Pakistan.
Abstract:
OBJECTIVE: The objective of this study was to compare the measurements of electronic and radiographic method of working lengths calculation with actual working length of root canals. Precise working length determination is the most important part for successful root canal procedure. The most commonly used methods to determine the working length in root canal treatment are radiography and electronic apex locator. METHODOLOGY: A cross sectional study was done over a period of 06 months in the Department of Operative Dentistry, Fatima Memorial Hospital, Lahore. Sixty patients who were recommended extraction of their premolar teeth with sixty canals were selected by convenience sampling. The Root ZX* apex locator was used to determine electronic working length exactly identifying the apical constriction. Reference points were identified and radiographic working length were determined 1mm short of radiographic apex. The teeth were extracted along with file cemented before extraction inside root canal. The actual length of the root canal was then calculated using the same files and reference point with 3.5X magnification. Pearson chisquare test was applied to compare the apex locator and digital radiographic measurement with actual working length. RESULTS: The Root ZX® apex locator was 95% accurate to identify the apical constriction as compared 70% accuracy given by radiographs within 0.5 mm of the apex. CONCLUSION: Electronic apex locator was more accurate as compared to digital radiography in working length determination.
Page(s): 24-28
DOI: DOI not available
Published: Journal: Journal of Pakistan Dental Association, Volume: 30, Issue: 1, Year: 2021
Keywords:
apical constriction , Working length WL , Electronic apex locators EAL , Radiographic working lengthRWL
References:
References are not available for this document.
Citations
Citations are not available for this document.
0

Citations

0

Downloads

2

Views