Wall heat transfer coefficients of Dowtherm - ❑ in-fixed beds.
Author(s):
1. M. M. Ahmad: Chemical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
2. J. R. Khan: Chemical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
3. G. M. Mamoor: Chemical Engineering Department, University of Engineering & Technology, Lahore, Pakistan
Abstract:
An experimental investigation into the effect of packing diameter, fluid velocity and thermal conductivity upon the wall heat transfer coefficients of Dowtherm-A, flowing in closed loop through a packed-bed reactor heated radially at the wall, has been made. Spherical and cylindrical shaped particles are employed as the packing material. A theoretical equation is developed which could predict the wall heat transfer coefficients of Dowtherm. The values of heat transfer coefficients so obtained are compared with the experimental data; an agreement is found within an accuracy of ±9%.
Page(s): 227-230
DOI: DOI not available
Published: Journal: Pakistan Journal of Scientific and Industrial Research, Volume: 29, Issue: 3, Year: 1986