Article Detail — Pakistan Science Abstracts

Choose Theme

Theme 1 — Green & Gold

No Detail Found!
The Role of Axillary SUVmax in F-FDG PET/CT in Predicting the Number of Axillary Metastases of Breast Cancer
Author(s)
Ufuk Karabacak Department of Surgical Oncology, Sivas Numune Hospital,Sivas,Turkiye
Halil Turkan Department of Surgical Oncology, Sanliurfa Mehmet Akif Inan Training and Research Hospital,Sanliurfa,Turkiye
Gokhan Coskun Department of Surgical Oncology, Tokat State Hospital,Tokat,Turkiye
Murat Can Mollaoglu Department of Surgical Oncology, Sivas Numune Hospital,Sivas,Turkiye
Zekiye Hasbek Department of Nuclear Medicine, Faculty of Medicine, Cumhuriyet University,Sivas,Turkiye
Kursat Karadayi Department of Surgical Oncology, Faculty of Medicine, Cumhuriyet University,Sivas,Turkiye
Abstract
Objective: To investigate the role of positron emission tomography/computed tomography (PET-CT) in determining the maximum number of axillary lymph node metastasis (ALNM) detectable in sentinel lymph node biopsy (SLNB). Study Design: Observational study. Place and Duration of the Study: Sivas Cumhuriyet University Faculty of Medicine, Turkiye, from January 2015 to August 2021. Methodology: A total of 104 breast cancer patients who underwent surgery after a PET-CT scan were examined. A receiver operating characteristic (ROC) analysis was utilised to determine optimal cut-o values for the standardised uptake values of the primary tumour (pSUVmax) and axillary lymph nodes (nSUVmax) in the presence of ALNM and the presence of more than two ALNMs. Results: The presence of more than two ALNMs was associated with pSUVmax, nSUVmax, LVI, and the number of LNs detected on PET-CT. In the ROC analysis, for the ability to predict more than two ALNMs in SLNB/axillary lymph node dissection (ALND), cut-o values were calculated as 4.65 for pSUVmax (AUC=0.669, sensitivity=66.7%, speci city=62%, PPV=0.482, NPV=0.800, p=0.006) and 1.75 for nSUVmax (AUC=0.838, sensitivity=81.8%, speci city=88.7%, PPV= 0.676, NPV=0.913, p<0.001). Conclusion: Low sensitivity, NPV, and accuracy values that limit the use of PET-CT in preoperative axillary evaluation can be increased by targeting the criterion of more than two ALNMs. Thus, PET-CT can be used more e ectively in axilla management.
Publication Details
Page(s) 374-379
DOI 10.29271/jcpsp.2023.04.374
Published Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 33, Issue: 4, Year: 2023
Keywords
Breast cancer ACOSOG Z0011 Axillary lymph node Positron emission tomography SUVmax values
References
References are not available for this document.
Citations