Pakistan Science Abstracts
Article details & metrics
No Detail Found!!
Technical Varieties of Ross Procedure: a Case Series.
Author(s):
1. Huma Fatima: The Aga Khan University Hospital, Karachi, Pakistan
2. Muneer Amanullah: Department of Surgery, The Aga Khan University Hospital, Karachi, Pakistan
3. Asif Hasan Siddiqui: Department of Surgery, The Aga Khan University Hospital, Karachi, Pakistan
4. Abdus Salam: The Aga Khan University Hospital, Karachi, Pakistan
5. Shirin Saeed: The Ziauddin University, Karachi, Pakistan
Abstract:
Replacement of aortic valve with the pulmonary autograft is carried out through the Ross procedure due to its potential for growth, durability in pediatric population, and absence of anticoagulation. This case series reports the postoperative outcome of two technical variations of Ross procedure in eight patients who underwent surgery from January 2007 to December 2016. The dominant valvular hemodynamic indication was aortic regurgitation. The techniques employed for Ross procedure included free standing root replacement in six patients and modified root replacement with autograft stabilisation using Dacron interposition graft in two patients. Right ventricular outflow tract (RVOT) conduit reconstruction was achieved by utilisation of Contegra bio prosthesis in four patients; and use of manually constructed valved conduit comprising of PTFE (polytetrafluoroethelene) membrane and bovine pericardial tube in remaining four patients. There was no mortality and no re-intervention. The technical varieties of Ross procedure offer freedom from need of anti-coagulation, mortality, and RVOT conduit failure in younger adults.
Page(s): 70-72
DOI: DOI not available
Published: Journal: Journal of College of Physicians and Surgeons--Pakistan : JCPSP, Volume: 29, Issue: 1, Year: 2019
Keywords:
Keywords are not available for this article.
References:
[1] LegarraJJ,ConchaM,CasaresJ,MerinoC,MuñozI,AladosP, 2001.Left ventricular remodeling after pulmonary autograft replacement of the aortic valve (Ross operation),J Heart Valve Dis 10 43 -8
[2] BerdajsDA,MuradbegovicM,HaselbachD,KofmehlR,SteurerJ,FerrariE, 2014.Ross procedure: is the root replacement technique superior to the sub-coronary implantation technique? Long-term results,Eur J Cardiothorac Surg 46 944 -51
[3] RossDN, 1967.Replacement of aortic and mitral valves with a pulmonary autograft,Lancet 2 956 -8
[4] StelzerP,JonesDJ,ElkinsRC, 1989.Aortic root replacement with pulmonary autograft,Circulation 80 III209 -13
[5] FrigiolaA,RanucciM,CarlucciC,GiambertiA,AbellaR,Di Donato M., 2008.The ross procedure in adults: long-term follow-up and echocardiographic changes leading to pulmonary autograft reoperation,Ann Thorac Surg 86 482 -9
[6] KlenaJW,ShweikiE,MahaffeyHW,WoodsEL,BenoitCH,GilbertCL, 2000.Annuloplasty and aortoplasty as modifications of the Ross procedure for the correction of geometric mismatch,J Heart Valve Dis 9 195 -9
[7] JuthierF,BanfiC,VincentelliA,EnnezatPV,Le TourneauT,PinçonC, 2010.Modified Ross operation with reinforcement of the pulmonary autograft: Six-year results,J Thorac Cardiovasc Surg 139 1420 -3
[8] CornoAF,HurniM,GriffinH,GalalOM,PayotM,SekarskiN, 2002.Bovine jugular vein as right ventricle-to-pulmonary artery valved conduit,J Heart Valve Dis 11 242 -7
[9] SierraJ,ChristensonJT,LahlaidiNH,BeghettiM,KalangosA, 2007.Right ventricular outflow tract reconstruction: what conduit to use? Homograft or Contegra?,Ann Thorac Surg 84 606 -10
[10] BrownJW,RuzmetovM,VijayP,RodefeldMD,TurrentineMW, 2007.Right ventricular outflow tract reconstruction with a polytetrafluoroethylenemonocusp valve: A twelve-year experience,J Thorac Cardiovasc Surg 133 1336 -43
Citations
Citations are not available for this document.
0

Citations

0

Downloads

3

Views