Pakistan Science Abstracts
Article details & metrics
No Detail Found!!
Transcatheter Closure of Patent Ductus Arteriosus through Only Venous Route.
Author(s):
1. Abdul Malik Sheikh: Rawalpindi Institute of Cardiology, Rawalpindi, Pakistan
2. Abdul Karim Duke: King Faisal Hospital, Jeddah, KSA
3. Hina Sattar: District Headquarter Hospital, Rawalpindi, Pakistan
Abstract:
Patent ductus arteriosus is a common congenital cardiac defect comprising 5-10% of all these defects in term neonates. Although open chest and video-assisted interruption are still in use, transcatheter occlusion has rapidly become the first choice for patent ductus arteriosus closure in the appropriate patient. Percutaneous closure of patent ductus arteriosus is widely done by transvenous approach guided by aortic access. We present the case of a 2 year old girl who underwent patent ductus arteriosus device occlusion with transvenous access only.
Page(s): 469-470
DOI: DOI not available
Published: Journal: Journal of Pakistan Medical Association, Volume: 68, Issue: 3, Year: 2018
Keywords:
Venous access , Device occlusion
References:
[1] Schneider DJ, Moore JW. Patent ductus arteriosus. Circulation. 2006; 114:1873-82.
[2] PorstmannW,WiernyL,WarnkeH,,1967,Closure of persistent ductus arteriosus without thoracotomy,Ger Med Mon,12,259,6
[3] KudumulaV,TaliotisD,DukeC.,,2015,The new occulotech duct occluder: Immediate results, procedural challenges and short term follow up,J Invasive Cardiol,27,1,8
[4] GhasemiA,PandyaS,ReddySV,TurnerDR,DuW,NavabiMA,,2010,Trans-catheter closure of patent ductus arteriosus-What is the best device? Catheter Cardiovasc Interv,,76,687,95
[5] AmmarRI,HegazyRA,,2012,Percutaneous closure of medium and large PDAs using amplatzer duct occluder (ADO) I and II in infants: safety and efficacy,J Invasive Cardiol,24,579,82
[6] FaellaHJ,HijaziZM,,2000,Closure of the patent ductus arteriosus with the amplatzer PDA device: immediate results of the international clinical trial,Catheter Cardiovasc Interv,51,50,4
[7] Baykan A, Narin N, Ozyurt A, Argun M, Pamuksu O, Nnan SH, et al. Do we need a femoral artery route for transvenous PDA closure in children with ADO-1. Anatol J Cardiol. 2015; 15:242-7.
[8] ZahnEM,NevinP,SimmonsC,Garg R,,2015,A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology,Cathet Cardiovasc Intervent,85,240,8
[9] ChenW,YanX,HuangY,SunX,ZhongL,LiJ,,2015,Transthoracic Echocardiography as an Alternative Major Guidance to Angiography During Transcatheter Closure of Patent Ductus Arteriosus: Technical Feasibility and Clinical Relevance,Pediatr Cardio,36,14,9
[10] SultanM,SadiqN,AkhterK,Akber H,,2014,Transcatheter closure of Patent ductus arteriosus,J Coll Phys Surg,24,710,13
[11] YounasM,BegA,,,Patent ductus arteriosus in young children less than 12kg-immediate results and complications,Pak Heart J.,,,
[12] Koch J, Hensley G, Roy L, Brown S, Ramaciotti C, Rosenfeld CR. Prevalence of spontaneous closure of the ductus arteriosus in neonates at a birth weight of 1000 grams or less. Pediatrics. 2006; 117:1113-21
Citations
Citations are not available for this document.
0

Citations

0

Downloads

8

Views