Pakistan Science Abstracts
Article details & metrics
No Detail Found!!
The Colour Density Spectral Array in the Perioperative Management of Urgent Craniectomy: Can We Identify Epileptiform Activity?.
Author(s):
1. Joana Barroso Moreira: Department of Anesthesiology, Critical Care & Emergency Medicine, Centro Hospitalar do Porto, Porto, Portugal; Emergency Physician in Pre-Hospital Emergency Services at Instituto Nacional de Emergência Médica in Porto, Portugal
2. Ana Luisa Veigade S: Department of Anesthesiology, Critical Care & Emergency Medicine, Centro Hospitalar do Porto, Porto, Portugal
3. Manuel Antnio Fernandes Trailada Silva Campos: Department of Anesthesiology, Critical Care & Emergency Medicine, Centro Hospitalar do Porto, Porto, Portugal
Abstract:
Status epilepticus (SE) represents a diagnostic and treatment challenge in comatosed patients. This clinic report represents one of the first descriptions of the use of Bilateral BIS® monitor to depict the changes of colour density spectral array (CDSA) from the operating room to the intensive care unit (ICU), and allowed us to hypothesize about the presence of epileptiform activity. A 45 years old man submitted to an urgent craniotomy directed to decompress a malignant middle cerebral artery infarct. Initial CDSA panel showed a pattern of asymmetry, related to the left hemisphere, where the ischemic-hemorrhagic lesion was located. A pattern of high power at frequencies under the 12Hz range was observed, resulting in a plateau formation that can imply seizure presence. This pattern responded to changing of Ce of target controlled infusion (TCI) Propofol and to a bolus of thiopental. At encephalic decompression a global reduction of activity at all frequencies was observed. The patient was transferred to the ICU where the DSA panel showed a sudden loss of alpha and then delta band frequencies. Cerebral death was afterwards clinically diagnosed. CDSA can be used as a complementary tool to detect and monitor SE. It shows good correlation with surgical events and anesthetic depth making it possible to tailor anesthesia to each patient needs in the operating room and in the ICU.
Page(s): 79-86
DOI: DOI not available
Published: Journal: Anaesthesia, Pain and Intensive Care, Volume: 21, Issue: 1, Year: 2017
Keywords:
Keywords are not available for this article.
References:
[1] ShahAM,VashiA,JagodaA, 2009.Review article: Convulsive and non-convulsive status epilepticus: An emergency medicine perspective,Emerg Med Australas 01212 6723 -66
[2] Hernández-HernándezMA,FernándezTorreJL,Ruiz-RuizA,Iglesias-PosadillaD,Gómez-MarcosV,Holanda-PeñaMS, 2014.Utilidad de la matriz de densidad espectral del sistema de índice biespectral bilateral en la monitorización del status epilepticus no convulsivo,Med Intensiva 38 265 -267
[3] Neurology, 2004., 62 1743 -1748
[4] 1980., 53 223 -236
[5] Hernández-HernándezMA, 2015.Color density spectral array of bilateral bispectral index system: Electroencephalographic correlate in comatose patients with nonconvulsive status epilepticus,Seizure 11 18 -25
[6] EscuderoD,OteroJ,MuñizG,GonzaloJA,CallejaC,GonzálezA,MusialowiczT,MervaalaE,KälviäinenR,UusaroA,RuokonenE,ParviainenI., 2005.The Bispectral Index Scale: Its Use in the Detection of Brain Death,Transplant Proc 37 3661 -3663
[7] CanBIS, 2009.monitoring be used to assess the depth of propofol anesthesia in the treatment of refractory status epilepticus?,Epilepsia 02514 1167 -1586
[8] Fernández-TorreJL, 2012.Utility of Bilateral Bispectral Index (BIS) Monitoring in a Comatose Patient with Focal Nonconvulsive Status Epilepticus,doi: 1 0 . 1 0 1 6 / j . s e i z u r e . 2 0 1 1 . 0 9 . 0 0 1 -64
[9] FàbregasN,GambúsPL,ValeroR,CarreroEJ,SalvadorL,ZavalaE, 2004.Can bispectral index monitoring predict recovery of consciousness in patients with severe brain injury?,Anesthesiology 101 43 -51
[10] LabovitzDL,HauserWA,SaccoRL, 2001.Prevalence and predictors of early seizure and status epilepticus after first stroke,Neurology 57 200 -206
[11] SmithCJ,EmsleyHCA,GavinCM,GeorgiouRF,VailA,BarberanEM, 2004.Peak plasma interleukin-6 and other peripheral markers of inflammation in the first week of ischaemic stroke correlate with brain infarct volume, stroke severity and long-term outcome,BMC Neurol 4 2 -
[12] StewartCP,OtsuboH,OchiA,SharmaR,HutchisonJS,HahnCD, 2010.Seizure identification in the ICU using quantitative EEG displays,Neurology 10 1501 -1508
[13] TallachRE,BallDR,JeffersonP, 2004.Monitoring seizures with the Bispectral index,Anaesthesia 59 1033 -1034
[14] PensirikulAD,BeslowLA,KesslerSK,SanchezSM,TopjianAA,DlugosDJ, 2013.Density spectral array for seizure identification in critically ill children,J Clin Neurophysiol 10 371 -375
[15] FriedmanDE,SchevonC,EmersonRG,HirschLJ, 2008.Cyclic electrographic seizures in critically ill patients,Epilepsia 49 281 -287
[16] Hernández-HernándezMÁ,IglesiasPosadillaD,Ruiz-RuizA,Gómez-MarcosV,Fernández-Torre JL, 2016.Colour Density Spectral Array of Bilateral Bispectral Index in Status Epilepticus, 85 44 -47
[17] SlottyPJ,KampMA,BeezT,BeenenH1,SteigerHJ1,TurowskiB, 2014.The influence of decompressive craniectomy for major stroke on early cerebral perfusion,J Neurosurg 10 59 -64
[18] ColtonK,YangS,HuP,ChenH,ScaleaT,SteinD., 2014.Hemodynamic changes after decompressive craniectomy for intracranial hypertension,Crit Care Med 42 -
[19] SantamarinaE,SueirasM,ToledoM,GuzmanL,TorneR,RiveiroM, 2015.Epilepsy in patients with malignant middle cerebral artery infarcts and decompressive craniectomies,Epilepsy Res 02 130 -136
[20] HermanST,AbendNS,BleckTP,ChapmanKE,DrislaneFW,EmersonRG, 2015.Consensus statement on continuous EEG in critically ill adults and children, part I: indications,J Clin Neurophysiol 10 87 -95
[21] ClaassenJ,TacconeFS,HornP,HoltkampM,StocchettiN,OddoM., .Recommendations on the use of EEG monitoring in critically ill patients: consensus statement from the neurointensive care section of the ESICM,Intensive Care Med 10 1337 -51
[22] DouL,Gao H-M , L u L,ChangW, 2014.Bispectral index in predicting the prognosis of patients with coma in intensive care unit,j . 1 9 2 0 - 8 6 4 2 . 2 0 1 4 . 0 1 9 -6
[23] VivienB,PaqueronX,Le CosquerP,LangeronO,CoriatP,RiouB, 2002.Detection of brain death onset using the bispectral index in severely comatose patients,Intensive Care Med 28 419 -425
[24] AlsterJ,PrattH,FeinsodM., 1993.Density spectral array, evoked potentials, and temperature rhythms in the evaluation and prognosis of the comatose patient,Brain Inj 7 191 -208
[25] Hernández-HernándezMÁ,FernándezTorreJL,Ruiz-RuizA,Holanda-PeñaMS, 2015.Color density spectral array in brain herniation],Rev Esp Anestesiol Reanim 62 58 -59
Citations
Citations are not available for this document.
0

Citations

0

Downloads

3

Views