Pakistan Science Abstracts
Article details & metrics
No Detail Found!!
Airway classification: Comparison of standard blade versus english blade of Macintosh laryngoscope.
Author(s):
1. Farzi Farnoush: Guilan University of Medical Science Iran
2. Mirmansouri Ali: Guilan University of Medical Science Iran
3. Heidarzadeh Abtin: Guilan University of Medical Science Iran
4. Tarbiat Masoud: Guilan University of Medical Science Iran
Abstract:
The optimal way for airway management is endotracheal intubation. Anesthesiologists use different kinds of laryngoscopes for tracheal intubation, but the most common laryngoscope is Macintosh laryngoscope with two blades; standard blade and English blade. Objective: Comparison of standard blade and English blade of Macintosh laryngoscope in airway classification of elective surgical patients. Materials and Methods: It was a prospective, single blind; clinical trial study that was done on seventy patients`s scheduled for elective surgery. They randomly classified into two groups (I, II). After induction of anesthesia and neuromuscular block in group I laryngoscopy was done at first with standard blade and then with English blade and in group II laryngoscopy was done at first with English blade and then standard blade inserted. The view of the glottis at laryngoscopy based on Cormack and Lehane scores were compared Results: There was a difference in the view of glottis in 15 patients. Among these patients the view was better for the English blade in 13 patients and the standard blade was better in 2 patients. Laryngoscopy was difficult (grade 3) for at least one blade in 3 patients. In 3 patients, the view was better for the English blade in 2 patients and for standard blade in 1 patient. The view of glottis as described by Cormack and Lehane for English blade was Grade I in 60 patients (85.7 %), Grade II in 9 patients (12.9 %), and this view for standard blade was: Grade I in 50 patients (71.4 %), Grade II in 18 patients (25.7 %). These differences were statistically significant (P = 0.006) Conclusion: Laryngoscopy with English blade provided a better view on glottis and lower score of Cormack & Lehane in comparison of standard blade of Macintosh laryngoscope.
Page(s): 479-483
DOI: DOI not available
Published: Journal: Professional Medical Journal, Volume: 14, Issue: 3, Year: 2007
Keywords:
Keywords are not available for this article.
References:
References are not available for this document.
Citations
Citations are not available for this document.
0

Citations

0

Downloads

2

Views