Pakistan Science Abstracts
Article details & metrics
No Detail Found!!
A study on Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Detecting Raised Intracranial Pressure in Intensive Care Unit Patients.
Author(s):
1. Renu Bala: Department of Anesthesiology and Critical Care, PT. B. D Sharma PGIMS, Rohtak Haryana, India
2. Arnab Banerjee: Department of Critical and Intensive Care, All India Institute of Medical Sciences (AIIMS), India
Abstract:
Introduction: Optic nerve sheath diameter (ONSD) using ocular ultrasound is increasingly used now a days as noninvasive means of detecting raised intracranial pressure. We conducted a cross-sectional, observational study to assess its validity, optimal cutof limit and inter-observer variability in our ICU patients. Methodology: The adult patients admitted to our ICU during six month interval (Jan 2014-June 2014) were enrolled for the study. The exclusion criteria were patients breathing spontaneously, presence of hyperthyroidism, optic nerve tumor, neuritis, glaucoma and orbital fracture. The patients were divided into two groups. Group I - those having increased ICP clinically or as per radiological findings. Group II - patients having no features of raised ICP. A linear probe with a frequency 13-7 MHz, SonositeTM USA, was used to measure ONSD by two blinded, experienced inveistgators. Mean of three readings was taken. The entire data was compiled and analyzed applying appropriate statiistcal tesst. Results: Total of 114 patients were enrolled and 100 completed the study; 65 in group I and 35 in group II. Mean ONSD in two groups were 0.62 ± 0.07 cm versus 0.476 ± 0.040 (p < 0.001); and 0.62 ± 0.07 versus 0.47 ± 0.042 (p < 0.001) in the right and left eye respectively. The inter-observer variability was nonsignificant, the sensitivity was 88.46%, specificity 93.54%, positive predictive value 95.83%, negative predictive value 82.85% where 5.0mm was taken as cutof limit.
Page(s): 432-437
DOI: DOI not available
Published: Journal: Anaesthesia, Pain and Intensive Care, Volume: 21, Issue: 4, Year: 2017
Keywords:
Keywords are not available for this article.
References:
[1] OpenForum Infect Dis, .,2014 Oct 10 -
[2] 2013.Noninvasive estimation of raised intracranial pressure using ocular ultrasonography in liver transplant recipients with acute liver failure -A report of two cases-,Korean J Anesthesiol 64 451 -455
[3] MannoE,MotevallianM,MfochiveA,NavarraM, 2013.,Ultrasonography Of The Optic Nerve Sheath Suggested Elevated Intracranial Pressure In Epilepsy: Case Report. Internet J Anesthesiol 26 -
[4] FagenholzPJ,GutmanJA,MurrayAF,NobleVE,CamargoCA, 1985.Optic nerve sheath diameter correlates with the presence and severity of acute mountain sickness: evidence for increased intracranial pressure,J Appl Physiol -
[5] 2007., 10 1207 -1211
[6] .Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients,Ann Emerg Med 49 508 -514
[7] Hwan KimY,Ho LeeJ,Kun HongC,Won ChoK,Hoon YeoJ,Ju KangM, .Feasibility of optic nerve sheath diameter measured on initial brain computed tomography as an early neurologic outcome predictor after cardiac arrest,Acad Emerg Med 10 1121 -1128
[8] LegrandA,JeanjeanP,DelangheF,PeltierJ,LecatB,Dupont H, .Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients,2013 Mar 10 -
[9] BallantyneSA,O'NeillG,HamiltonR,HollmanSA, 2002.Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adult,Eur J Ultrasound 15 145 -9
[10] ShevlinC, 2015.Optic Nerve Sheath Ultrasound for the Bedside Diagnosis of Intracranial Hypertension: Pitfalls and Potential,Critical Care Horizons 1 22 -30
[11] Jun-Jul, .The American Association of neurological Surgeons. The joint Section on Neurotrauma and Critical Care. Indications for intracranial pressure monitoring,J.Neurotrauma 17 479 -91
[12] RajajeeV,VanamanM,FletcherJJ,JacobsTL, 2011.Optic nerve ultrasound for the detection of raised intracranial pressure,Neurocrit Care 10 506 -15
[13] ShirodkarCG,RaoSM,MutkuleDP,HardeYR,VenkategowdaPM,MaheshMU, .Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study,Indian J Crit Care Med 18 728 -34
[14] HamiltonDR,SargsyanAE,MeltonSL,GarciaKM,OddoB,KwonDS, .Sonography for determining the optic nerve sheath diameter with increasing intracranial pressure in a porcine model,J Ultrasound Med 30 651 -659
[15] HansenHC,HelmkeK., 1997.Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests,J Neurosurg 87 34 -40
[16] KimberlyHH,ShahS,MarillK,NobleV, .Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure,Acad Emerg Med 15 201 -204
[17] QayyumH,Ramlakhan S, .Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department,Eur J Emerg Med 10 91 -97
[18] BlaivasM,TheodoroD,SierzenskiPR, .Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath,Acad Emerg Med 10 376 -381
[19] LazzaroA,WeigelM,HansenHC,HennigJ,BleyTA, ., -
[20] 2007.Morphometry of the retrobulbar human optic nerve: comparison between conventional sonography and ultrafast magnetic resonance sequences,Invest Ophthalmol Vis Sci 48 1913 -1917
[21] WatanabeA,KinouchiH,HorikoshiT,UchidaM, 2008.Ishigame K. Effect of intracranial pressure on the diameter of the optic nerve sheath,J Neurosurg 10 255 -258
Citations
Citations are not available for this document.
0

Citations

0

Downloads

10

Views