A novel and Low Processing Time ECG Security Method Suitable for Sensor Node Platforms.
Author(s):
1. Jusak Jusak: Dept. of Computer Engineering, Institute of Business and Informatics Stikom Surabaya, Surabaya, Indonesia
2. Seed Ahmed S Mahmoud: Dept. Of Electrical and Electronis Technology, Riyadh Applied Engineering College, Riyadh, Kingdom of Saudi Arabic
Abstract:
An anonymisation of electrocardiogram (ECG) signal is essential during the distribution and storage in a public repository. In this paper, we introduce a novel low processing time ECG anonymisation method employing the fast Fourier transform (FFT) method. The proposed framework is suitable for sensor node platforms due to its low processing time. It was developed to address two major inherent limitations in the Internet of Medical Thing (IMedT) environment including most current requirement for securing ECG signal and urgent need for efficient methods to overcome physical limitation of sensor nodes. Ramifications from computer simulation showed that the proposed model was able to obscure both fiducial and non-fiducial features of the ECG signals. Performance evaluation between the original and the reconstructed ECG signals revealed strong cross-correlation implying lossless reconstruction of the original ECG signal. Furthermore, the proposed method achieved a lower processing time security algorithm as compared with the recently proposed wavelet based anonymisation methods. Finally, the proposed framework offered advantages in terms of flexibility in determining the secret key length makes it suitable for various applications.
Page(s): 213-241
DOI: DOI not available
Published: Journal: International Journal of Communication Networks and Information Security, Volume: 10, Issue: 1, Year: 2018
Keywords:
Keywords are not available for this article.
References:
[1] CiscoVNI, 2017.-networking-index-vni/vni-hyperconnectivitywp,html. Accessed on 21 July -
[2] L.Atzori,A.Iera, 2010.Internet of Things: a survey,” Computer Networks, 15 2787 -2805
[3] A.U.Rehman,S.U.Rehman,I.K.Khan,M.Moiz,S.Hasan, 2016.Security and privacy issues in IoT,International Journal of Communication Networks and Information Security 8 147 -157
[4] J.G.Andrews,S.Buzzi,W.Choi,S.V.Hanly,A.Lozano,C.K. Soong , J.C.,Zhang, 2014.,” IEEE Journal of Selected Areas in Communications 32 1065 -1082
[5] S.M.R.Islam,D.Kwak,M.D.H. Kabir , M.,Hossain , K.S.,Kwak, 2015.Internet of Things for health care: a comprehensive survey,” IEEE Access 3 678 -708
[6] J.Jusak,I. Puspasari, 2015.Wireless tele-auscultation for phonocardiograph signal recording through the zigbee networks,” IEEE Asia Pacific Conference on Wireless and Mobile (APWiMob) 27 -29
[7] J.Jusak,H.Pratikno,V.H.Putra, 2016.Internet of Medical Things for cardiac monitoring: paving the way to 5G mobile networks,” IEEE Int. Conference on Communication, Networks and Satellite (COMNETSAT 75 -79
[8] L.Biel,O.Petersson,L.Philipson,P.Wide, 2001.ECG analysis: a new approach in human identification,” IEEE Transactions on Instrumentation and Measurement 50 808 -812
[9] I.Odinaka,P.Lai,A.D.Kaplan,J.A. O'Sullivan , E.J.,Sirevaag , J.W.,Rohrbaugh, 2012.ECG biometric recognition: a comparative analysis,” IEEE Transactions on Information Forensics and Security 7 1812 -1824
[10] F.Sufi,S.S.Mahmoud,and I. Khalil, 2008.A novel wavelet packet-based anti-spoofing technique to secure ECG data,International Journal of Biometrics 1 191 -208
[11] F.Sufi,I. Khalil, 2008.Enforcing secured ECG transmission for realtime monitoring: a joint encoding, compression and encryption mechanism,” Security and Communication Networks, 1 389 -405
[12] T.Oluvan,C.E.A.Chambell,S.Hole,K.Radhakrishnan,A.Sedigh, 2014.Mitigating external threats in wireless local area networks,International Journal of Communication Networks and Information Security 6 200 -216
[13] ServicesUSA,Services, 2007.Security 101 for covered entities HIPAA Security Series (2, 1 -11
[14] European Parliament and of the Council, “Directive 95/46/EC of the European Parliament and of the Council: on the protection of individuals with regards to the processing of personal data and on the free movement of such data,” Official Journal of European Communities (1), No. 281, pp. 31-50, Oct. 1995.
[15] PrivacyCommisioner, 2008., -
[16] C.Pearce,M.Bainbridge, 2014.A personally controlled electronic health record for Australia,” Journal of the American Medical Informatics Association, 21 707 -713
[17] S.S.Mahmmoud, 2016.A generalized wavelet packet-based anonymisation approach for ECG security application,” Security and Communication Networks, 18 6137 -6147
[18] F.Hu,S.Lakdawala,Q.Hao,M.Qiu, 2009.Low-power, intelligent sensor hardware interface for medical data preprocessing,” IEEE Transactions on Information Technology in Biomedicine 13 656 -663
[19] A.Sa-ngasoongsong,Kunthong , V.,Sarangan , X.,Cai, 2012.A low-cost, portable, high-throughput wireless sensor system for phonocardiography applications, 12 10851 -10870
[20] T.Narmadha,M.Kalaiarasi,M.Meenakshi, 2017.Lightweight secure ECG transmission in wireless body area networks - PRESENT chipper based implementation,” International Conference on Communications and Signal Processing 1066 -1070
[21] N.Bhushan, 2014.“Network densification: the dominant theme for wireless evolution into 5G,” IEEE Communications Magazine, 52 82 -89
[22] E.Hossain,M.Hasan, 2015.5G Cellular: key enabling technologies,” IEEE Instrumentation and Measurement Magazine 18 11 -21
[23] I.F.Akyildiz, 2016.“5G roadmap: 10 keys enabling technologies,” Computer Networks, 106 17 -48
[24] V.K.Murthy,T.M.Grove, 1978.Clinical usefulness of ECG frequency spectrum analysis,” Annual Symposium on Computer Applications in Medical Care 9 Nov -
[25] L.Sornmo,P.Laguna, 2006.Electrocardiogram (ECG) signal processing, -
[26] The PTB Diagnostic ECG, .Database (Physionet), -
[27] MIT-BIH Arrhythmia, ., -
[28] B.M.Kaplan,R.Langendorf,M.Lev,A.Pick, 1973.Tachycardia-bradycardia syndrome (so-called: sick sinus syndrome): pathology, mechanisms and treatment,American Journal of Cardiology 31 497 -508
Citations
Citations are not available for this document.
0

Citations

0

Downloads

25

Views