Abstract:
In this paper we consider a single unit system with N spares and K repair facilities. The system fails when the spares are emptied. It is assumed that repair tie and failure time have the exponential distributions with parameters µ and X, respectively. We are interested in determining the expected time to system failure, the long-run availability of the system and also to know the number of spares and repair facilities required to achieve a pre assigned long-run availability for given values of l and µ.
Page(s):
58-61
DOI:
DOI not available
Published:
Journal: Punjab University Journal of Mathematics, Volume: 27, Issue: , Year: 1994